{"id":414,"date":"2025-03-21T03:25:47","date_gmt":"2025-03-21T03:25:47","guid":{"rendered":"http:\/\/23.27.11.206\/?p=414"},"modified":"2025-03-24T03:17:23","modified_gmt":"2025-03-24T03:17:23","slug":"hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear","status":"publish","type":"post","link":"https:\/\/pineele.com\/cs\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear","title":{"rendered":"HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>\u00davod<\/strong><\/h2>\n\n\n\n<p>Na str\u00e1nk\u00e1ch <strong>HXGN17-12 Ring Main Unit (RMU)<\/strong> is a compact, high-performance <strong>medium voltage switchgear<\/strong> designed for use in <strong>power <a href=\"https:\/\/pineele.com\/cs\/srm6-12-gas-insulated-switchgear\/\">distribution<\/a> systems<\/strong> up to <strong>12kV<\/strong>. It provides a reliable, <strong>fully insulated<\/strong>a <strong>fully enclosed<\/strong> switching solution, ensuring <strong>safe and efficient operation<\/strong> in <strong>industrial, commercial, and utility applications<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"702\" height=\"1024\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-7-702x1024.webp\" alt=\"\" class=\"wp-image-490\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-7-702x1024.webp 702w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-7-206x300.webp 206w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-7-768x1120.webp 768w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-7.webp 790w\" sizes=\"(max-width: 702px) 100vw, 702px\" \/><\/figure>\n\n\n\n<p>This <strong>RMU<\/strong> is widely used in urban and rural power grids, industrial plants, commercial centers, railways, substations, and infrastructure projects where <strong>continuous power supply and compact design<\/strong> are essential.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Kl\u00ed\u010dov\u00e9 vlastnosti<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Compact &amp; Modular Design<\/strong>: Small footprint, making it ideal for urban substations and space-constrained installations.<\/li>\n\n\n\n<li><strong>High Reliability<\/strong>: Fully insulated, fully enclosed structure, and maintenance-free operation.<\/li>\n\n\n\n<li><strong>Enhanced Safety<\/strong>: Arc-resistant design with <strong>vacuum load switch<\/strong> technology to improve operational safety.<\/li>\n\n\n\n<li><strong>Flexible Configurations<\/strong>: Can be configured for <strong>ring network or radial power distribution<\/strong>.<\/li>\n\n\n\n<li><strong>Long Electrical Life<\/strong>: Designed for <strong>high operational endurance<\/strong>, ensuring long-term performance with minimal maintenance.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" width=\"790\" height=\"743\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-.webp\" alt=\"Working Conditions\" class=\"wp-image-418\" style=\"width:840px;height:auto\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-.webp 790w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit--300x282.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit--768x722.webp 768w\" sizes=\"(max-width: 790px) 100vw, 790px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Working Conditions<\/strong><\/h2>\n\n\n\n<p>To ensure the best performance and longevity, the <strong>HXGN17-12 RMU<\/strong> is designed to operate under the following environmental conditions:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Parametr<\/strong><\/th><th><strong>Specifikace<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Okoln\u00ed teplota<\/strong><\/td><td>-25\u00b0C a\u017e +40\u00b0C<\/td><\/tr><tr><td><strong>Nadmo\u0159sk\u00e1 v\u00fd\u0161ka<\/strong><\/td><td>\u2264 1000m<\/td><\/tr><tr><td><strong>Relativn\u00ed vlhkost<\/strong><\/td><td>Daily avg. \u2264 95%, Monthly avg. \u2264 90%<\/td><\/tr><tr><td><strong>Seismick\u00e1 odolnost<\/strong><\/td><td>Up to Magnitude 8<\/td><\/tr><tr><td><strong>Podm\u00ednky prost\u0159ed\u00ed<\/strong><\/td><td>No fire, explosion risk, corrosive gas, or heavy pollution<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Technick\u00e9 specifikace<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>General Electrical Specifications<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Parametr<\/strong><\/th><th><strong>Unit<\/strong><\/th><th><strong>FN12-12<\/strong><\/th><th><strong>FZN25-12<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Jmenovit\u00e9 nap\u011bt\u00ed<\/strong><\/td><td>kV<\/td><td>12<\/td><td>12<\/td><\/tr><tr><td><strong>1-Min Frequency Withstand Voltage<\/strong><\/td><td>kV<\/td><td>42 (to ground), 48 (isolation breaks)<\/td><td>42 (to ground), 48 (isolation breaks)<\/td><\/tr><tr><td><strong>Lightning Impulse Voltage (Peak)<\/strong><\/td><td>kV<\/td><td>75 (to ground), 85 (isolation breaks)<\/td><td>75 (to ground), 85 (isolation breaks)<\/td><\/tr><tr><td><strong>Rated Frequency<\/strong><\/td><td>Hz<\/td><td>50<\/td><td>50<\/td><\/tr><tr><td><strong>Jmenovit\u00fd proud<\/strong><\/td><td>A<\/td><td>630<\/td><td>630<\/td><\/tr><tr><td><strong>Electrical Life at Rated Current<\/strong><\/td><td>Cycles<\/td><td>\u2265100<\/td><td>\u2265100<\/td><\/tr><tr><td><strong>Open No-Load Transformer Capacity<\/strong><\/td><td>kVA<\/td><td>1250<\/td><td>1250<\/td><\/tr><tr><td><strong>Rated Stabilizer<\/strong><\/td><td>kA\/S<\/td><td>20\/4, Earth Switch 20\/2<\/td><td>20\/4, Earth Switch 20\/2<\/td><\/tr><tr><td><strong>Rated Dynamic Stabilizing Current (Peak)<\/strong><\/td><td>kA<\/td><td>50<\/td><td>50<\/td><\/tr><tr><td><strong>Rated Short Circuit Closing Current (Peak)<\/strong><\/td><td>kA<\/td><td>50<\/td><td>50<\/td><\/tr><tr><td><strong>Fuse Rated Current<\/strong><\/td><td>A<\/td><td>125<\/td><td>125<\/td><\/tr><tr><td><strong>Rated Transfer Current<\/strong><\/td><td>A<\/td><td>870<\/td><td>870<\/td><\/tr><tr><td><strong>Rated Short-Circuit Opening Current<\/strong><\/td><td>kA<\/td><td>20<\/td><td>20<\/td><\/tr><tr><td><strong>Matching Fuse Type<\/strong><\/td><td>&#8211;<\/td><td>S\u25a1LAJ-12<\/td><td>S\u25a1LAJ-12<\/td><\/tr><tr><td><strong>Mechanick\u00e1 \u017eivotnost<\/strong><\/td><td>Cycles<\/td><td>2000<\/td><td>10000<\/td><\/tr><tr><td><strong>Auxiliary Circuit 1-min Frequency Withstand Voltage<\/strong><\/td><td>kV<\/td><td>2<\/td><td>2<\/td><\/tr><tr><td><strong>Electric Actuator Working Voltage<\/strong><\/td><td>V<\/td><td>AC\/DC 220, 110<\/td><td>AC\/DC 220, 110<\/td><\/tr><tr><td><strong>Protection Grade<\/strong><\/td><td>&#8211;<\/td><td>IP2X<\/td><td>IP2X<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"790\" height=\"789\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-03.webp\" alt=\"Installation &amp; Mounting Dimensions\" class=\"wp-image-419\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-03.webp 790w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-03-300x300.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-03-150x150.webp 150w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-03-768x767.webp 768w\" sizes=\"(max-width: 790px) 100vw, 790px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Installation &amp; Mounting Dimensions<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Standard Dimensions (mm)<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>W<\/strong><\/th><th><strong>D<\/strong><\/th><th><strong>H<\/strong><\/th><\/tr><\/thead><tbody><tr><td>600<\/td><td>900<\/td><td>2000<\/td><\/tr><tr><td>650<\/td><td>900<\/td><td>2000<\/td><\/tr><tr><td>700<\/td><td>900<\/td><td>2000<\/td><\/tr><tr><td>800<\/td><td>900<\/td><td>2000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"577\" height=\"1024\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-04-577x1024.webp\" alt=\"Installation Diagram &amp; Components\" class=\"wp-image-420\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-04-577x1024.webp 577w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-04-169x300.webp 169w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-04-768x1362.webp 768w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-Ring-Main-Unit-04.webp 790w\" sizes=\"(max-width: 577px) 100vw, 577px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Installation Diagram &amp; Components<\/strong><\/h2>\n\n\n\n<p>Na str\u00e1nk\u00e1ch <strong>HXGN17-12 RMU<\/strong> consists of various <strong>functional compartments<\/strong> and key components:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Instrument Door<\/strong>: Houses control instruments and metering units.<\/li>\n\n\n\n<li><strong>Instrumentation<\/strong>: Includes meters and protective relays.<\/li>\n\n\n\n<li><strong>DXN Display<\/strong>: Displays operational status.<\/li>\n\n\n\n<li><strong>Nameplate<\/strong>: Identification label with product details.<\/li>\n\n\n\n<li><strong>Operating Mechanism<\/strong>: Switchgear control section.<\/li>\n\n\n\n<li><strong>Lower Door<\/strong>: Provides access for maintenance.<\/li>\n\n\n\n<li><strong>Analog Plate<\/strong>: Displays schematic representation.<\/li>\n\n\n\n<li><strong>Door Lock<\/strong>: Enhances security.<\/li>\n\n\n\n<li><strong>Load Switch<\/strong>: Vacuum switch mechanism.<\/li>\n\n\n\n<li><strong>Center Divider<\/strong>: Structural reinforcement.<\/li>\n\n\n\n<li><strong>Skeleton<\/strong>: Structural frame.<\/li>\n\n\n\n<li><strong>Current Transformer<\/strong>: Measures current flow.<\/li>\n\n\n\n<li><strong>Cable Holder<\/strong>: Supports cable routing.<\/li>\n\n\n\n<li><strong>Relay Compartment<\/strong>: Houses protective relay units.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Ordering Information<\/strong><\/h2>\n\n\n\n<p>When placing an order for the <strong>HXGN17-12 Ring Main Unit<\/strong>, the following <strong>technical data should be provided<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Main Wiring Scheme Number<\/strong>: Define purpose and system diagram.<\/li>\n\n\n\n<li><strong>Rated Voltage &amp; Current<\/strong>: Specify the operational voltage.<\/li>\n\n\n\n<li><strong>Short Circuit Breaking Capacity<\/strong>: Required fault-handling capability.<\/li>\n\n\n\n<li><strong>Room Layout Plan<\/strong>: Space arrangement details.<\/li>\n\n\n\n<li><strong>Protection &amp; Control Requirements<\/strong>: Include schematic diagrams.<\/li>\n\n\n\n<li><strong>Environmental Considerations<\/strong>: For special conditions.<\/li>\n\n\n\n<li><strong>Custom Requirements<\/strong>: Any additional configurations.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Applications of HXGN17-12 Ring Main Unit<\/strong><\/h2>\n\n\n\n<p>Na str\u00e1nk\u00e1ch <strong>HXGN17-12 RMU<\/strong> is ideal for <strong>medium-voltage power distribution networks<\/strong> and provides a <strong>safe and efficient solution<\/strong> in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Urban &amp; Rural Power Distribution<\/strong>: Used in industrial and commercial electrical networks.<\/li>\n\n\n\n<li><strong>Renewable Energy Projects<\/strong>: Suitable for <strong>solar and wind power stations<\/strong>.<\/li>\n\n\n\n<li><strong>Underground &amp; Indoor Substations<\/strong>: Compact and enclosed for confined spaces.<\/li>\n\n\n\n<li><strong>Railway &amp; Metro Networks<\/strong>: Used in <strong>train stations and underground metro networks<\/strong>.<\/li>\n\n\n\n<li><strong>Industrial Plants &amp; Mining<\/strong>: Essential for <strong>factories, refineries, and mining operations<\/strong>.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Advantages of HXGN17-12 RMU<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Kompaktn\u00ed design<\/strong> \u2013 Small footprint, <strong>saving installation space<\/strong>.<\/li>\n\n\n\n<li><strong>Fully Insulated &amp; Sealed<\/strong> \u2013 No exposure to dust, moisture, or pollutants.<\/li>\n\n\n\n<li><strong>Low Maintenance<\/strong> \u2013 <strong>Minimal servicing required<\/strong> over its lifetime.<\/li>\n\n\n\n<li><strong>Fast &amp; Easy Installation<\/strong> \u2013 Preassembled units ensure <strong>quick deployment<\/strong>.<\/li>\n\n\n\n<li><strong>Long Lifespan<\/strong> \u2013 <strong>Durable materials<\/strong> for extended operational life.<\/li>\n\n\n\n<li><strong>Safe &amp; Reliable<\/strong> \u2013 Built-in <strong>arc-proof<\/strong> a <strong>fault-handling mechanisms<\/strong>.<\/li>\n\n\n\n<li><strong>Customizable Configurations<\/strong> \u2013 Adaptable for <strong>various network requirements<\/strong>.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>Na str\u00e1nk\u00e1ch <strong>HXGN17-12 Ring Main Unit (RMU)<\/strong> is a <strong>state-of-the-art medium voltage switchgear solution<\/strong> designed for <strong>modern power distribution networks<\/strong>. It offers <strong>reliable performance, compact design, and enhanced safety features<\/strong>, making it an <strong>ideal choice<\/strong> for <strong>utility providers, industrial facilities, and renewable energy projects<\/strong>.<\/p>\n\n\n\n<p>With its <strong>versatile configurations<\/strong>, robust <strong>vacuum load switch technology<\/strong>a <strong>fully insulated enclosure<\/strong>, the <strong>HXGN17-12 RMU<\/strong> delivers <strong>exceptional efficiency<\/strong> a <strong>long-term reliability<\/strong> in <strong>medium voltage power distribution applications<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction The HXGN17-12 Ring Main Unit (RMU) is a compact, high-performance medium voltage switchgear designed for use in power distribution systems up to 12kV. It provides a reliable, fully insulated, and fully enclosed switching solution, ensuring safe and efficient operation in industrial, commercial, and utility applications. This RMU is widely used in urban and rural [&hellip;]<\/p>","protected":false},"author":1,"featured_media":491,"comment_status":"closed","ping_status":"open","sticky":true,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[12],"tags":[],"class_list":["post-414","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ring-main-unit"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear - PINEELE<\/title>\n<meta name=\"description\" content=\"The HXGN17-12 Ring Main Unit (RMU) is a compact, high-performance medium voltage switchgear designed for use in power distribution systems up to 12kV. It provides a reliable, fully insulated, and fully enclosed switching solution, ensuring safe and efficient operation in industrial, commercial, and utility applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pineele.com\/cs\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear\" \/>\n<meta property=\"og:locale\" content=\"cs_CZ\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear - PINEELE\" \/>\n<meta property=\"og:description\" content=\"The HXGN17-12 Ring Main Unit (RMU) is a compact, high-performance medium voltage switchgear designed for use in power distribution systems up to 12kV. It provides a reliable, fully insulated, and fully enclosed switching solution, ensuring safe and efficient operation in industrial, commercial, and utility applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pineele.com\/cs\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear\" \/>\n<meta property=\"og:site_name\" content=\"PINEELE\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-21T03:25:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-24T03:17:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-2-2.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"songshu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Napsal(a)\" \/>\n\t<meta name=\"twitter:data1\" content=\"songshu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Odhadovan\u00e1 doba \u010dten\u00ed\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#article\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear\"},\"author\":{\"name\":\"songshu\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\"},\"headline\":\"HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear\",\"datePublished\":\"2025-03-21T03:25:47+00:00\",\"dateModified\":\"2025-03-24T03:17:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear\"},\"wordCount\":713,\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-2-2.webp\",\"articleSection\":[\"Ring Main Unit (RMU)\"],\"inLanguage\":\"cs\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear\",\"url\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear\",\"name\":\"HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear - PINEELE\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#primaryimage\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-2-2.webp\",\"datePublished\":\"2025-03-21T03:25:47+00:00\",\"dateModified\":\"2025-03-24T03:17:23+00:00\",\"description\":\"The HXGN17-12 Ring Main Unit (RMU) is a compact, high-performance medium voltage switchgear designed for use in power distribution systems up to 12kV. It provides a reliable, fully insulated, and fully enclosed switching solution, ensuring safe and efficient operation in industrial, commercial, and utility applications.\",\"breadcrumb\":{\"@id\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#breadcrumb\"},\"inLanguage\":\"cs\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#primaryimage\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-2-2.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-2-2.webp\",\"width\":800,\"height\":800},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/pineele.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/pineele.com\/#website\",\"url\":\"https:\/\/pineele.com\/\",\"name\":\"PINEELE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/pineele.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"cs\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/pineele.com\/#organization\",\"name\":\"PINEELE\",\"url\":\"https:\/\/pineele.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"width\":200,\"height\":50,\"caption\":\"PINEELE\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\",\"name\":\"songshu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"cs\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"caption\":\"songshu\"},\"sameAs\":[\"https:\/\/pineele.com\/\"],\"url\":\"https:\/\/pineele.com\/cs\/author\/songshu\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear - PINEELE","description":"The HXGN17-12 Ring Main Unit (RMU) is a compact, high-performance medium voltage switchgear designed for use in power distribution systems up to 12kV. It provides a reliable, fully insulated, and fully enclosed switching solution, ensuring safe and efficient operation in industrial, commercial, and utility applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pineele.com\/cs\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear","og_locale":"cs_CZ","og_type":"article","og_title":"HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear - PINEELE","og_description":"The HXGN17-12 Ring Main Unit (RMU) is a compact, high-performance medium voltage switchgear designed for use in power distribution systems up to 12kV. It provides a reliable, fully insulated, and fully enclosed switching solution, ensuring safe and efficient operation in industrial, commercial, and utility applications.","og_url":"https:\/\/pineele.com\/cs\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear","og_site_name":"PINEELE","article_published_time":"2025-03-21T03:25:47+00:00","article_modified_time":"2025-03-24T03:17:23+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-2-2.webp","type":"image\/webp"}],"author":"songshu","twitter_card":"summary_large_image","twitter_misc":{"Napsal(a)":"songshu","Odhadovan\u00e1 doba \u010dten\u00ed":"5 minut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#article","isPartOf":{"@id":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear"},"author":{"name":"songshu","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3"},"headline":"HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear","datePublished":"2025-03-21T03:25:47+00:00","dateModified":"2025-03-24T03:17:23+00:00","mainEntityOfPage":{"@id":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear"},"wordCount":713,"publisher":{"@id":"https:\/\/pineele.com\/#organization"},"image":{"@id":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-2-2.webp","articleSection":["Ring Main Unit (RMU)"],"inLanguage":"cs"},{"@type":"WebPage","@id":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear","url":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear","name":"HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear - PINEELE","isPartOf":{"@id":"https:\/\/pineele.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#primaryimage"},"image":{"@id":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-2-2.webp","datePublished":"2025-03-21T03:25:47+00:00","dateModified":"2025-03-24T03:17:23+00:00","description":"The HXGN17-12 Ring Main Unit (RMU) is a compact, high-performance medium voltage switchgear designed for use in power distribution systems up to 12kV. It provides a reliable, fully insulated, and fully enclosed switching solution, ensuring safe and efficient operation in industrial, commercial, and utility applications.","breadcrumb":{"@id":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#breadcrumb"},"inLanguage":"cs","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear"]}]},{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#primaryimage","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-2-2.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/HXGN17-12-2-2.webp","width":800,"height":800},{"@type":"BreadcrumbList","@id":"https:\/\/pineele.com\/hxgn17-12-ring-main-unit-rmu-medium-voltage-switchgear#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pineele.com\/"},{"@type":"ListItem","position":2,"name":"HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear"}]},{"@type":"WebSite","@id":"https:\/\/pineele.com\/#website","url":"https:\/\/pineele.com\/","name":"PINEELE","description":"","publisher":{"@id":"https:\/\/pineele.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pineele.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"cs"},{"@type":"Organization","@id":"https:\/\/pineele.com\/#organization","name":"PINEELE","url":"https:\/\/pineele.com\/","logo":{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","width":200,"height":50,"caption":"PINEELE"},"image":{"@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3","name":"songshu","image":{"@type":"ImageObject","inLanguage":"cs","@id":"https:\/\/pineele.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","caption":"songshu"},"sameAs":["https:\/\/pineele.com\/"],"url":"https:\/\/pineele.com\/cs\/author\/songshu"}]}},"_links":{"self":[{"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/posts\/414","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/comments?post=414"}],"version-history":[{"count":4,"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/posts\/414\/revisions"}],"predecessor-version":[{"id":494,"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/posts\/414\/revisions\/494"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/media\/491"}],"wp:attachment":[{"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/media?parent=414"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/categories?post=414"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pineele.com\/cs\/wp-json\/wp\/v2\/tags?post=414"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}