لمحة عامة
إنDFW Outdoor Intelligent Box-Type Switchgearمتقدمmedium-voltagedistribution unitdesigned forpower distribution networks. It is widely utilized inurban and rural power grids, substations, industrial facilities, and renewable energy systemsto ensureefficient, safe, and reliableelectrical distribution.

Thisswitchgear systemfeatureshigh insulation performance, modular design, and intelligent control capabilities, making it an ideal choice for modernsmart grid applications.
الميزات الرئيسية
- High VoltageCapacity: Operates at12 كيلو فولت, ensuring stability inmedium-voltage applications.
- Compact & Modular Structure: Designed forspace-saving installationsin various environments.
- Fully Sealed & Insulated: Provides protection againstmoisture, dust, and environmental contaminants.
- Multi-Loop Configurations: Supportsvarious power distribution schemes.
- Superior Safety Features: Includesshort-circuit protection, lightning arresters, and overload safeguards.
- Low Maintenance & High Durability: Built withhigh-quality materialsfor extended service life.

Environmental Conditions for Product Use
Condition | المواصفات |
---|---|
Altitude | ≤1000 m |
Maximum Ambient Temperature | +40°C |
Minimum Ambient Temperature | -25°C |
Maximum Daily Temperature Difference | 25K |
Relative Humidity (Indoor) | Daily Average ≤95%, Monthly Average ≤90% |
Earthquake Resistance | 0.2g horizontal acceleration, 0.1g vertical acceleration |
بيئة التثبيت | Free of gas, steam, dust, corrosive chemicals |
Grounding System | Suitable fornon-grounding systems and 10kV grounded systems |
Main Technical Parameters
الرقم التسلسلي | الاسم | Unit | Load Switch Cabinet | Combination Electrical Cabinet |
1 | الفولتية المقدرة | kV | 12 | 12 |
2 | Rated Frequency | Hz | 50 | 50 |
3 | التيار المقنن | A | 630 | 200 |
4 | Rated Load Break Current | A | 630 | 630 |
5 | Rated Short-Term Withstand Current | kA | 20 | 20 |
6 | Rated Short Circuit Duration | s | 3 | 3 |
7 | تيار ذروة التحمل المقدر | kA | 50/63 | 50/63 |
8 | Closed Loop Break Current | A | 630 | 630 |
9 | Rated Cable Charging & Disconnection Current | A | 25 | 25 |
10 | Rated No-Load Transformer Break Current | A | 16 | 16 |
11 | Rated Switch Current | A | 1750 | 1750 |
12 | Fuse Expected Short Circuit Breaking Current | kA | 63 | 63 |
13 | Ground Switch Withstand Current | kA/1s | 25 | 25 |
14 | Rated Current Break Times | Times | ≥200 | ≥200 |
15 | الحياة الميكانيكية | Times | ≥2000 | ≥2000 |
16 | SF6 Gas Annual Leakage Rate | % | Not more than 1% | Not more than 1% |
Structural & Installation Diagram
التطبيقات
إنDFW Outdoor Intelligent Box-Type Switchgearis suitable for:
- Power Transmission & Distribution Networks
- Substations & Industrial Facilities
- Urban & Rural Power Grids
- Renewable Energy Projects (Wind & Solar Farms)
- Underground & Overhead Cable Networks
Installation Guidelines
Pre-Installation Checklist
- Ensure theinstallation site meets grounding and safety requirements.
- تحققcable ducts and foundation preparations.
- Inspect allcable branch terminals and insulation components.
خطوات التثبيت
- Prepare the Foundation:Ensure properalignment and base reinforcement.
- Position the Switchgear Cabinet:Secure it usingmounting brackets and bolts.
- Connect the Incoming & Outgoing Cables:تأكد منproper insulation and safety clearances.
- Grounding Setup:Establish asafe earthing systemfor fault protection.
- Final Testing & Commissioning:Conductvoltage withstand tests, insulation resistance measurements, and functional checks.
Advantages of Our DFW Switchgear
- Enhanced Electrical Safety:Designed withadvanced fault isolation mechanisms.
- Modular & Scalable Configuration:Supportsvarious circuit arrangements.
- Weather-Resistant & Durable:Built forharsh outdoor conditions.
- Seamless Smart Grid Integration:Compatible withSCADA and remote monitoring systems.

Ordering Information
To customize yourDFW Outdoor Intelligent Box-Type Switchgear, please provide:
- Rated Voltage & Current Requirements
- Branch & Loop Configurations
- Enclosure Material & Protection Level
- Additional Accessories (Lightning Arresters, Fault Indicators, etc.)