{"id":1215,"date":"2025-04-03T08:14:21","date_gmt":"2025-04-03T08:14:21","guid":{"rendered":"https:\/\/pineele.com\/?p=1215"},"modified":"2025-04-03T08:14:47","modified_gmt":"2025-04-03T08:14:47","slug":"xrnt-current-limiting-fuses-for-transformer-protection","status":"publish","type":"post","link":"https:\/\/pineele.com\/hu\/xrnt-current-limiting-fuses-for-transformer-protection","title":{"rendered":"XRNT Current-limiting Fuses for Transformer Protection"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Introduction<\/h2>\n\n\n\n<p>A&nbsp;<strong>XRNT Current-Limiting Fuses<\/strong>&nbsp;are engineered to protect transformers and electrical equipment in&nbsp;<strong>3.6kV to 40.5kV<\/strong>&nbsp;indoor AC 50Hz systems. Designed to operate seamlessly with load switches, vacuum contactors, and switchgear, these fuses provide critical defense against overloads and short circuits. Ideal for high-voltage switchgear, ring main units, and substations, the XRNT series ensures reliable performance in demanding industrial and utility environments.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Key Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Wide Voltage Range<\/strong>: Compatible with\u00a0<strong>3.6kV, 7.2kV, 12kV, 24kV, and 40.5kV<\/strong>\u00a0systems.<\/li>\n\n\n\n<li><strong>High Breaking Capacity<\/strong>: Efficiently interrupts fault currents to safeguard transformers.<\/li>\n\n\n\n<li><strong>Precision Protection<\/strong>: Customizable fuse ratings from\u00a0<strong>3.15A to 250A<\/strong>\u00a0for tailored solutions.<\/li>\n\n\n\n<li><strong>Robust Construction<\/strong>: Durable design for long-term reliability in indoor installations.<\/li>\n\n\n\n<li><strong>Versatile Integration<\/strong>: Essential accessory for switchgear, RMUs, and substations.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">M\u0171szaki specifik\u00e1ci\u00f3k<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Table 1: XRNT Fuse Series Electrical Parameters<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Type<\/th><th>Rated Voltage (kV)<\/th><th>Rated Current of Fuse (A)<\/th><th>Rated Current of Fuselink (A)<\/th><\/tr><\/thead><tbody><tr><td>XRNT-12<\/td><td>12<\/td><td>40<\/td><td>3.15, 6.3, 10, 16, 20, 25, 31.5, 40<\/td><\/tr><tr><td>XRNT-12<\/td><td>12<\/td><td>100<\/td><td>50, 63, 71, 80, 100, (125)<\/td><\/tr><tr><td>XRNT-12<\/td><td>12<\/td><td>125<\/td><td>125, 160, 200, 250<\/td><\/tr><tr><td>XRNT-24<\/td><td>24<\/td><td>200<\/td><td>3.15, 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63, 80, 100, 125, 160, 200<\/td><\/tr><tr><td>XRNT-40.5<\/td><td>40.5<\/td><td>125<\/td><td>3.15, 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63, 80, 100, 125, 160, 200<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Overall and Mounting Dimensions (mm)<\/h2>\n\n\n\n<p><strong>Chat1\/a link XRNT-12Kv<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"979\" height=\"320\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160534.webp\" alt=\"Chat1\/a link XRNT-12Kv\" class=\"wp-image-1216\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160534.webp 979w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160534-300x98.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160534-768x251.webp 768w\" sizes=\"(max-width: 979px) 100vw, 979px\" \/><\/figure>\n\n\n\n<p>Note: \u03a6A: \u03a651mm&nbsp;( 6.3-40A ) \u03a663\u03a676mm&nbsp;(&nbsp;50-125A )&nbsp;\u03a688mm&nbsp;(&nbsp;160-200A )<\/p>\n\n\n\n<p><strong>Chat2\/a\u00a0link\u00a0XRNT\u00a0\u25a1-24Kv<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"301\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160535-1024x301.webp\" alt=\"Chat2\/a\u00a0link\u00a0XRNT\u00a0\u25a1-24Kv\" class=\"wp-image-1217\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160535-1024x301.webp 1024w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160535-300x88.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160535-768x226.webp 768w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160535.webp 1103w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Note:\u03a6A:&nbsp;\u03a651mm&nbsp;(&nbsp;6.3-40A )&nbsp;\u03a663&nbsp;\u03a676mm&nbsp;(&nbsp;50-125A )&nbsp;\u03a688mm&nbsp;(&nbsp;125-20OA)<\/p>\n\n\n\n<p><strong>Chat3\/a\u00a0link\u00a0XRNT\u00a0\u25a1-40.5Kv<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1003\" height=\"412\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160537.webp\" alt=\"Chat3\/a\u00a0link\u00a0XRNT\u00a0\u25a1-40.5Kv\" class=\"wp-image-1218\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160537.webp 1003w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160537-300x123.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160537-768x315.webp 768w\" sizes=\"(max-width: 1003px) 100vw, 1003px\" \/><\/figure>\n\n\n\n<p>Note: \u03a6A: \u03a651mm&nbsp;( 6.3-25A ) \u03a676mm&nbsp;(&nbsp;25-40A )&nbsp;\u03a688mm&nbsp;(&nbsp;50-100A )<\/p>\n\n\n\n<p><strong>Chat4\/b\u00a0link(12Kv)<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"421\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160538-1024x421.webp\" alt=\"\" class=\"wp-image-1219\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160538-1024x421.webp 1024w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160538-300x123.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160538-768x316.webp 768w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160538.webp 1119w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Chat5\/Inserting type fuse\u00a0XRNT\u25a1-24Kv<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"839\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160539-1024x839.webp\" alt=\"Chat5\/Inserting type fuse XRNT\u25a1-24Kv\" class=\"wp-image-1220\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160539-1024x839.webp 1024w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160539-300x246.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160539-768x629.webp 768w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160539.webp 1039w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>Chat6\/Insertingfypefuse\u00a0XRNT\u25a1-40.5Kv<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"725\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160540-1024x725.webp\" alt=\"Chat6\/Insertingfypefuse XRNT\u25a1-40.5Kv\" class=\"wp-image-1221\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160540-1024x725.webp 1024w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160540-300x212.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160540-768x544.webp 768w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160540.webp 1241w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Example Dimension Guide (Customize with Your Diagrams):<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Modell<\/th><th>A (mm)<\/th><th>B (mm)<\/th><th>C (mm)<\/th><th>D (mm)<\/th><th>Reference Diagram<\/th><\/tr><\/thead><tbody><tr><td>XRNT-12<\/td><td>150<\/td><td>200<\/td><td>300<\/td><td>50<\/td><td>Figure 1<\/td><\/tr><tr><td>XRNT-24<\/td><td>180<\/td><td>220<\/td><td>320<\/td><td>60<\/td><td>Figure 2<\/td><\/tr><tr><td>XRNT-40.5<\/td><td>200<\/td><td>250<\/td><td>350<\/td><td>70<\/td><td>Figure 3<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><em>(Replace with your specific dimension charts or images.)<\/em><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Alkalmaz\u00e1sok<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Transformer Protection<\/strong>: Safeguards distribution and power transformers from overloads.<\/li>\n\n\n\n<li><strong>Switchgear Integration<\/strong>: Compatible with high-voltage switchgear and RMUs.<\/li>\n\n\n\n<li><strong>Industrial Power Systems<\/strong>: Protects motors, capacitors, and critical equipment.<\/li>\n\n\n\n<li><strong>Renewable Energy<\/strong>: Ensures safety in solar\/wind farm substations.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Why Choose XRNT Fuses?<\/h2>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li><strong>Adaptive Design<\/strong>: Supports a broad range of currents (3.15A\u2013250A) for diverse applications.<\/li>\n\n\n\n<li><strong>High Voltage Compatibility<\/strong>: Covers systems up to\u00a0<strong>40.5kV<\/strong>\u00a0for utility and industrial use.<\/li>\n\n\n\n<li><strong>Reliable Fault Interruption<\/strong>: Limits damage by swiftly isolating faulty circuits.<\/li>\n\n\n\n<li><strong>Certified Quality<\/strong>: Complies with international electrical safety standards.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Installation &amp; Maintenance<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Mounting<\/strong>: Follow dimension diagrams for precise alignment in switchgear or panels.<\/li>\n\n\n\n<li><strong>Fuse Selection<\/strong>: Match fuselink ratings to system requirements (refer to Table 1).<\/li>\n\n\n\n<li><strong>Inspection<\/strong>: Regularly monitor for signs of wear or thermal stress.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>A&nbsp;<strong>XRNT Current-Limiting Fuse Series<\/strong>&nbsp;delivers unmatched protection for transformers and high-voltage systems. With its flexible ratings (3.15A\u2013250A), wide voltage compatibility (3.6kV\u201340.5kV), and robust construction, it is the go-to solution for ensuring operational safety and minimizing downtime in critical infrastructure.<\/p>\n\n\n\n<p><strong>Upgrade your protection system today\u2014contact us for technical details and pricing!<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction The&nbsp;XRNT Current-Limiting Fuses&nbsp;are engineered to protect transformers and electrical equipment in&nbsp;3.6kV to 40.5kV&nbsp;indoor AC 50Hz systems. Designed to operate seamlessly with load switches, vacuum contactors, and switchgear, these fuses provide critical defense against overloads and short circuits. Ideal for high-voltage switchgear, ring main units, and substations, the XRNT series ensures reliable performance in demanding [&hellip;]<\/p>","protected":false},"author":1,"featured_media":1223,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[33],"tags":[],"class_list":["post-1215","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-high-voltage-fuse"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>XRNT Current-limiting Fuses for Transformer Protection - PINEELE<\/title>\n<meta name=\"description\" content=\"Discover XRNT Current-Limiting Fuses for transformer protection\u20143.6kV to 40.5kV systems, 3.15A\u2013250A ratings. Explore specs, applications, and mounting guides.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pineele.com\/hu\/xrnt-current-limiting-fuses-for-transformer-protection\" \/>\n<meta property=\"og:locale\" content=\"hu_HU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"XRNT Current-limiting Fuses for Transformer Protection - PINEELE\" \/>\n<meta property=\"og:description\" content=\"Discover XRNT Current-Limiting Fuses for transformer protection\u20143.6kV to 40.5kV systems, 3.15A\u2013250A ratings. Explore specs, applications, and mounting guides.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pineele.com\/hu\/xrnt-current-limiting-fuses-for-transformer-protection\" \/>\n<meta property=\"og:site_name\" content=\"PINEELE\" \/>\n<meta property=\"article:published_time\" content=\"2025-04-03T08:14:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-03T08:14:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160542.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"songshu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Szerz\u0151:\" \/>\n\t<meta name=\"twitter:data1\" content=\"songshu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Becs\u00fclt olvas\u00e1si id\u0151\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 perc\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#article\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection\"},\"author\":{\"name\":\"songshu\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\"},\"headline\":\"XRNT Current-limiting Fuses for Transformer Protection\",\"datePublished\":\"2025-04-03T08:14:21+00:00\",\"dateModified\":\"2025-04-03T08:14:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection\"},\"wordCount\":455,\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160542.webp\",\"articleSection\":[\"High-Voltage Fuse\"],\"inLanguage\":\"hu\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection\",\"url\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection\",\"name\":\"XRNT Current-limiting Fuses for Transformer Protection - PINEELE\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#primaryimage\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160542.webp\",\"datePublished\":\"2025-04-03T08:14:21+00:00\",\"dateModified\":\"2025-04-03T08:14:47+00:00\",\"description\":\"Discover XRNT Current-Limiting Fuses for transformer protection\u20143.6kV to 40.5kV systems, 3.15A\u2013250A ratings. Explore specs, applications, and mounting guides.\",\"breadcrumb\":{\"@id\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#breadcrumb\"},\"inLanguage\":\"hu\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#primaryimage\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160542.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160542.webp\",\"width\":800,\"height\":800},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/pineele.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"XRNT Current-limiting Fuses for Transformer Protection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/pineele.com\/#website\",\"url\":\"https:\/\/pineele.com\/\",\"name\":\"PINEELE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/pineele.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"hu\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/pineele.com\/#organization\",\"name\":\"PINEELE\",\"url\":\"https:\/\/pineele.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"width\":200,\"height\":50,\"caption\":\"PINEELE\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\",\"name\":\"songshu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"caption\":\"songshu\"},\"sameAs\":[\"https:\/\/pineele.com\/\"],\"url\":\"https:\/\/pineele.com\/hu\/author\/songshu\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"XRNT Current-limiting Fuses for Transformer Protection - PINEELE","description":"Discover XRNT Current-Limiting Fuses for transformer protection\u20143.6kV to 40.5kV systems, 3.15A\u2013250A ratings. Explore specs, applications, and mounting guides.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pineele.com\/hu\/xrnt-current-limiting-fuses-for-transformer-protection","og_locale":"hu_HU","og_type":"article","og_title":"XRNT Current-limiting Fuses for Transformer Protection - PINEELE","og_description":"Discover XRNT Current-Limiting Fuses for transformer protection\u20143.6kV to 40.5kV systems, 3.15A\u2013250A ratings. Explore specs, applications, and mounting guides.","og_url":"https:\/\/pineele.com\/hu\/xrnt-current-limiting-fuses-for-transformer-protection","og_site_name":"PINEELE","article_published_time":"2025-04-03T08:14:21+00:00","article_modified_time":"2025-04-03T08:14:47+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160542.webp","type":"image\/webp"}],"author":"songshu","twitter_card":"summary_large_image","twitter_misc":{"Szerz\u0151:":"songshu","Becs\u00fclt olvas\u00e1si id\u0151":"4 perc"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#article","isPartOf":{"@id":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection"},"author":{"name":"songshu","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3"},"headline":"XRNT Current-limiting Fuses for Transformer Protection","datePublished":"2025-04-03T08:14:21+00:00","dateModified":"2025-04-03T08:14:47+00:00","mainEntityOfPage":{"@id":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection"},"wordCount":455,"publisher":{"@id":"https:\/\/pineele.com\/#organization"},"image":{"@id":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160542.webp","articleSection":["High-Voltage Fuse"],"inLanguage":"hu"},{"@type":"WebPage","@id":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection","url":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection","name":"XRNT Current-limiting Fuses for Transformer Protection - PINEELE","isPartOf":{"@id":"https:\/\/pineele.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#primaryimage"},"image":{"@id":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160542.webp","datePublished":"2025-04-03T08:14:21+00:00","dateModified":"2025-04-03T08:14:47+00:00","description":"Discover XRNT Current-Limiting Fuses for transformer protection\u20143.6kV to 40.5kV systems, 3.15A\u2013250A ratings. Explore specs, applications, and mounting guides.","breadcrumb":{"@id":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#breadcrumb"},"inLanguage":"hu","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection"]}]},{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#primaryimage","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160542.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/04\/20250403160542.webp","width":800,"height":800},{"@type":"BreadcrumbList","@id":"https:\/\/pineele.com\/xrnt-current-limiting-fuses-for-transformer-protection#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pineele.com\/"},{"@type":"ListItem","position":2,"name":"XRNT Current-limiting Fuses for Transformer Protection"}]},{"@type":"WebSite","@id":"https:\/\/pineele.com\/#website","url":"https:\/\/pineele.com\/","name":"PINEELE","description":"","publisher":{"@id":"https:\/\/pineele.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pineele.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"hu"},{"@type":"Organization","@id":"https:\/\/pineele.com\/#organization","name":"PINEELE","url":"https:\/\/pineele.com\/","logo":{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","width":200,"height":50,"caption":"PINEELE"},"image":{"@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3","name":"songshu","image":{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/pineele.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","caption":"songshu"},"sameAs":["https:\/\/pineele.com\/"],"url":"https:\/\/pineele.com\/hu\/author\/songshu"}]}},"_links":{"self":[{"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/posts\/1215","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/comments?post=1215"}],"version-history":[{"count":2,"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/posts\/1215\/revisions"}],"predecessor-version":[{"id":1226,"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/posts\/1215\/revisions\/1226"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/media\/1223"}],"wp:attachment":[{"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/media?parent=1215"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/categories?post=1215"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pineele.com\/hu\/wp-json\/wp\/v2\/tags?post=1215"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}