{"id":682,"date":"2025-03-25T02:52:48","date_gmt":"2025-03-25T02:52:48","guid":{"rendered":"https:\/\/pineele.com\/?p=682"},"modified":"2025-03-25T02:52:50","modified_gmt":"2025-03-25T02:52:50","slug":"sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","status":"publish","type":"post","link":"https:\/\/pineele.com\/ja\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","title":{"rendered":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution"},"content":{"rendered":"<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n\n<p>\u306b\u3064\u3044\u3066 <strong>SZ\u25a1-35KV Oil-Immersed <a href=\"https:\/\/pineele.com\/ja\/electrical-transformer\/oil-immersed-transformer\/\">\u5909\u5727\u5668<\/a><\/strong> is a highly efficient, on-load voltage regulating transformer designed for power systems operating at 35kV and below. Operating under a frequency of 50Hz, this transformer is a key component in medium and small-sized substations. It provides reliable power distribution for industrial, agricultural, and lighting applications.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"789\" height=\"726\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\" alt=\"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems\" class=\"wp-image-683\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp 789w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621-300x276.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621-768x707.webp 768w\" sizes=\"(max-width: 789px) 100vw, 789px\" \/><\/figure>\n\n\n\n<p>Manufactured with precision and built using advanced domestic and international technology, the SZ\u25a1-35KV transformer incorporates optimized design techniques and modern materials. This results in a more compact structure, enhanced electric and mechanical strength, and superior heat dissipation performance.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Standards Compliance<\/h2>\n\n\n\n<p>This transformer complies with national and international quality standards ensuring safety, durability, and efficient operation.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Operating Conditions<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u9ad8\u5ea6<\/strong>: \u22641000m<\/li>\n\n\n\n<li><strong>\u5468\u56f2\u6e29\u5ea6<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Maximum: +40\u2103<\/li>\n\n\n\n<li>Monthly Average: +30\u2103<\/li>\n\n\n\n<li>Yearly Average: +20\u2103<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Installation Conditions<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Maximum inclination: &lt;3\u00b0<\/li>\n\n\n\n<li>Free from significant dust, corrosive gases, and flammable vapors<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Structural Features<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Iron Core<\/h3>\n\n\n\n<p>The iron core is fabricated using high-grade cold-rolled silicon steel sheets. The core design incorporates:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fully biased multi-stage joints<\/li>\n\n\n\n<li>Non-punch hole wind cores<\/li>\n\n\n\n<li>Stainless steel stays and epoxy glass tape reinforcement<\/li>\n<\/ul>\n\n\n\n<p>This structure minimizes energy losses and reduces operational noise, ensuring long-term performance.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"996\" height=\"247\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105201854.webp\" alt=\"Structural Features\" class=\"wp-image-684\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105201854.webp 996w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105201854-300x74.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105201854-768x190.webp 768w\" sizes=\"(max-width: 996px) 100vw, 996px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">2. Coil Design<\/h3>\n\n\n\n<p>The winding conductors are manufactured from high-purity oxygen-free copper wires, available as enameled wire or paper-wrapped flat copper wire. The coil structures include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Drum type<\/li>\n\n\n\n<li>Spiral type<\/li>\n\n\n\n<li>Improved spiral<\/li>\n\n\n\n<li>Continuous winding<\/li>\n\n\n\n<li>Staggered layout<\/li>\n<\/ul>\n\n\n\n<p>This design ensures uniform distribution of magnetic flux and prevents hot-spot formation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Oil Tank<\/h3>\n\n\n\n<p>The oil tank is available in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Barrel-type or shielded construction<\/li>\n\n\n\n<li>Corrugated plates or electroplated radiators for cooling<\/li>\n<\/ul>\n\n\n\n<p>Instead of wheels, the base is welded to meet national gauge standards for stable, fixed installation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Safety &amp; Protection Devices<\/h3>\n\n\n\n<p>Based on customer and standard requirements, the transformer can be equipped with:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pressure relief valve<\/li>\n\n\n\n<li>Gas relay<\/li>\n\n\n\n<li>Signal thermometer<\/li>\n\n\n\n<li>Oil conservator<\/li>\n\n\n\n<li>Oil sample valve<\/li>\n\n\n\n<li>Oil filter system<\/li>\n<\/ul>\n\n\n\n<p>These features ensure system integrity during overvoltage or fault conditions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u6280\u8853\u4ed5\u69d8<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">SZ9-35KV Transformer Technical Data<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Rated Capacity (kVA)<\/th><th>H.V (kV)<\/th><th>Tapping Range<\/th><th>L.V (kV)<\/th><th>Connection<\/th><th>No-load Loss (W)<\/th><th>Load Loss (W)<\/th><th>No-load Current (%)<\/th><th>Impedance (%)<\/th><\/tr><tr><td>2000<\/td><td>35<\/td><td>\u00b13\u00d72.5<\/td><td>6.3\/10.5<\/td><td>Yd11<\/td><td>2900<\/td><td>20200<\/td><td>0.9<\/td><td>6.5<\/td><\/tr><tr><td>2500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>3400<\/td><td>22700<\/td><td>0.9<\/td><td><\/td><\/tr><tr><td>3150<\/td><td>35-38.5<\/td><td><\/td><td><\/td><td><\/td><td>4100<\/td><td>26000<\/td><td>0.8<\/td><td>7<\/td><\/tr><tr><td>4000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>4900<\/td><td>30700<\/td><td>0.8<\/td><td><\/td><\/tr><tr><td>5000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>5800<\/td><td>36000<\/td><td>0.75<\/td><td><\/td><\/tr><tr><td>6300<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>7000<\/td><td>38700<\/td><td>0.75<\/td><td>8<\/td><\/tr><tr><td>8000<\/td><td><\/td><td><\/td><td><\/td><td>Ynd11<\/td><td>9900<\/td><td>43000<\/td><td>0.7<\/td><td><\/td><\/tr><tr><td>10000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>11600<\/td><td>50600<\/td><td>0.7<\/td><td><\/td><\/tr><tr><td>12500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>13800<\/td><td>59900<\/td><td>0.7<\/td><td><\/td><\/tr><tr><td>16000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>16200<\/td><td>73000<\/td><td>0.7<\/td><td><\/td><\/tr><tr><td>20000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>19500<\/td><td>84600<\/td><td>0.7<\/td><td><\/td><\/tr><tr><td>25000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>22500<\/td><td>100200<\/td><td>0.7<\/td><td>10<\/td><\/tr><tr><td>31500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>26400<\/td><td>124000<\/td><td>0.6<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">SZ11-35KV Transformer Technical Data<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Rated Capacity (kVA)<\/td><td>H.V (kV)<\/td><td>Tapping Range<\/td><td>L.V (kV)<\/td><td>Connection<\/td><td>No-load Loss (W)<\/td><td>Load Loss (W)<\/td><td>No-load Current (%)<\/td><td>Impedance (%)<\/td><\/tr><tr><td>2000<\/td><td>35<\/td><td>\u00b13\u00d72.5<\/td><td>6.3\/10.5<\/td><td>Yd11<\/td><td>2300<\/td><td>19240<\/td><td>0.8<\/td><td>6.5<\/td><\/tr><tr><td>2500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>2720<\/td><td>20640<\/td><td>0.8<\/td><td><\/td><\/tr><tr><td>3150<\/td><td>35-38.5<\/td><td><\/td><td><\/td><td><\/td><td>3230<\/td><td>24710<\/td><td>0.72<\/td><td>7<\/td><\/tr><tr><td>4000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>3870<\/td><td>29160<\/td><td>0.72<\/td><td><\/td><\/tr><tr><td>5000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>4640<\/td><td>31200<\/td><td>0.68<\/td><td><\/td><\/tr><tr><td>6300<\/td><td><\/td><td><\/td><td>6.3\/6.6\/10.5<\/td><td>Ynd11<\/td><td>5630<\/td><td>36770<\/td><td>0.68<\/td><td>7.5<\/td><\/tr><tr><td>8000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>7870<\/td><td>40610<\/td><td>0.6<\/td><td><\/td><\/tr><tr><td>10000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>9280<\/td><td>48050<\/td><td>0.6<\/td><td><\/td><\/tr><tr><td>12500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>10940<\/td><td>56860<\/td><td>0.56<\/td><td>8<\/td><\/tr><tr><td>16000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>13170<\/td><td>70320<\/td><td>0.54<\/td><td><\/td><\/tr><tr><td>20000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>15570<\/td><td>82780<\/td><td>0.54<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">SZ13-35KV Transformer Technical Data<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Rated Capacity (kVA)<\/td><td>H.V (kV)<\/td><td>Tapping Range<\/td><td>L.V (kV)<\/td><td>Connection<\/td><td>No-load Loss (W)<\/td><td>Load Loss (W)<\/td><td>No-load Current (%)<\/td><td>Impedance (%)<\/td><\/tr><tr><td>2000<\/td><td>35<\/td><td>\u00b13\u00d72.5<\/td><td>6.3\/10.5<\/td><td>Yd11<\/td><td>2300<\/td><td>19200<\/td><td>0.5<\/td><td>6.5<\/td><\/tr><tr><td>2500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>2720<\/td><td>20600<\/td><td>0.5<\/td><td><\/td><\/tr><tr><td>3150<\/td><td>35-38.5<\/td><td><\/td><td><\/td><td><\/td><td>3230<\/td><td>24700<\/td><td>0.5<\/td><td>7<\/td><\/tr><tr><td>4000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>3870<\/td><td>29100<\/td><td>0.5<\/td><td><\/td><\/tr><tr><td>5000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>4640<\/td><td>34200<\/td><td>0.5<\/td><td><\/td><\/tr><tr><td>6300<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>5630<\/td><td>36700<\/td><td>0.5<\/td><td>8<\/td><\/tr><tr><td>8000<\/td><td><\/td><td><\/td><td>6.3\/6.6\/10.5<\/td><td>Ynd11<\/td><td>7870<\/td><td>40600<\/td><td>0.4<\/td><td><\/td><\/tr><tr><td>10000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>9280<\/td><td>48000<\/td><td>0.4<\/td><td><\/td><\/tr><tr><td>12500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>1090<\/td><td>56800<\/td><td>0.35<\/td><td><\/td><\/tr><tr><td>16000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>1310<\/td><td>70300<\/td><td>0.35<\/td><td><\/td><\/tr><tr><td>20000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>1550<\/td><td>82100<\/td><td>0.35<\/td><td><\/td><\/tr><tr><td>25000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>1830<\/td><td>97800<\/td><td>0.3<\/td><td>10<\/td><\/tr><tr><td>31500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>2180<\/td><td>716000<\/td><td>0.3<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. What is the purpose of an oil-immersed transformer in modern power systems?<\/h3>\n\n\n\n<p>Oil-immersed transformers provide efficient insulation and superior heat dissipation, making them suitable for medium-voltage networks and industrial applications.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. How does the SZ\u25a1-35KV transformer support voltage regulation?<\/h3>\n\n\n\n<p>The SZ\u25a1-35KV transformer features on-load voltage regulation capability, allowing it to adapt to grid voltage fluctuations in real time without service interruption.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. What makes this transformer energy-efficient?<\/h3>\n\n\n\n<p>With advanced materials, optimized coil and core designs, and reduced no-load and load losses, this transformer significantly improves overall energy efficiency.<\/p>","protected":false},"excerpt":{"rendered":"<p>Overview The SZ\u25a1-35KV Oil-Immersed Transformer is a highly efficient, on-load voltage regulating transformer designed for power systems operating at 35kV and below. Operating under a frequency of 50Hz, this transformer is a key component in medium and small-sized substations. It provides reliable power distribution for industrial, agricultural, and lighting applications. Manufactured with precision and built using advanced domestic and international technology, the SZ\u25a1-35KV transformer incorporates optimized design techniques and modern materials. This results in a more compact structure, enhanced electric and mechanical strength, and superior heat dissipation performance. Standards Compliance This transformer complies with national and international quality standards ensuring safety, durability, and efficient operation. Operating Conditions Structural Features 1. [&hellip;]<\/p>","protected":false},"author":1,"featured_media":683,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[24],"tags":[],"class_list":["post-682","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oil-immersed-transformer"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE<\/title>\n<meta name=\"description\" content=\"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pineele.com\/ja\/sz\u25a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE\" \/>\n<meta property=\"og:description\" content=\"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pineele.com\/ja\/sz\u25a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\" \/>\n<meta property=\"og:site_name\" content=\"PINEELE\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-25T02:52:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-25T02:52:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"789\" \/>\n\t<meta property=\"og:image:height\" content=\"726\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"songshu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"songshu\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"4\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#article\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\"},\"author\":{\"name\":\"songshu\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\"},\"headline\":\"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution\",\"datePublished\":\"2025-03-25T02:52:48+00:00\",\"dateModified\":\"2025-03-25T02:52:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\"},\"wordCount\":499,\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\",\"articleSection\":[\"Oil-Immersed Transformer\"],\"inLanguage\":\"ja\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\",\"url\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\",\"name\":\"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\",\"datePublished\":\"2025-03-25T02:52:48+00:00\",\"dateModified\":\"2025-03-25T02:52:50+00:00\",\"description\":\"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.\",\"breadcrumb\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\",\"width\":789,\"height\":726},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/pineele.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/pineele.com\/#website\",\"url\":\"https:\/\/pineele.com\/\",\"name\":\"PINEELE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/pineele.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/pineele.com\/#organization\",\"name\":\"PINEELE\",\"url\":\"https:\/\/pineele.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"width\":200,\"height\":50,\"caption\":\"PINEELE\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\",\"name\":\"songshu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"caption\":\"songshu\"},\"sameAs\":[\"https:\/\/pineele.com\/\"],\"url\":\"https:\/\/pineele.com\/ja\/author\/songshu\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE","description":"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pineele.com\/ja\/sz\u25a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","og_locale":"ja_JP","og_type":"article","og_title":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE","og_description":"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.","og_url":"https:\/\/pineele.com\/ja\/sz\u25a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","og_site_name":"PINEELE","article_published_time":"2025-03-25T02:52:48+00:00","article_modified_time":"2025-03-25T02:52:50+00:00","og_image":[{"width":789,"height":726,"url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp","type":"image\/webp"}],"author":"songshu","twitter_card":"summary_large_image","twitter_misc":{"\u57f7\u7b46\u8005":"songshu","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"4\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#article","isPartOf":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution"},"author":{"name":"songshu","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3"},"headline":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution","datePublished":"2025-03-25T02:52:48+00:00","dateModified":"2025-03-25T02:52:50+00:00","mainEntityOfPage":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution"},"wordCount":499,"publisher":{"@id":"https:\/\/pineele.com\/#organization"},"image":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp","articleSection":["Oil-Immersed Transformer"],"inLanguage":"ja"},{"@type":"WebPage","@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","url":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","name":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE","isPartOf":{"@id":"https:\/\/pineele.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage"},"image":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp","datePublished":"2025-03-25T02:52:48+00:00","dateModified":"2025-03-25T02:52:50+00:00","description":"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.","breadcrumb":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp","width":789,"height":726},{"@type":"BreadcrumbList","@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pineele.com\/"},{"@type":"ListItem","position":2,"name":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution"}]},{"@type":"WebSite","@id":"https:\/\/pineele.com\/#website","url":"https:\/\/pineele.com\/","name":"PINEELE","description":"","publisher":{"@id":"https:\/\/pineele.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pineele.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Organization","@id":"https:\/\/pineele.com\/#organization","name":"PINEELE","url":"https:\/\/pineele.com\/","logo":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","width":200,"height":50,"caption":"PINEELE"},"image":{"@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3","name":"songshu","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/pineele.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","caption":"songshu"},"sameAs":["https:\/\/pineele.com\/"],"url":"https:\/\/pineele.com\/ja\/author\/songshu"}]}},"_links":{"self":[{"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/posts\/682","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/comments?post=682"}],"version-history":[{"count":2,"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/posts\/682\/revisions"}],"predecessor-version":[{"id":686,"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/posts\/682\/revisions\/686"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/media\/683"}],"wp:attachment":[{"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/media?parent=682"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/categories?post=682"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pineele.com\/ja\/wp-json\/wp\/v2\/tags?post=682"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}