{"id":668,"date":"2025-03-25T02:28:14","date_gmt":"2025-03-25T02:28:14","guid":{"rendered":"https:\/\/pineele.com\/?p=668"},"modified":"2025-03-25T02:28:15","modified_gmt":"2025-03-25T02:28:15","slug":"xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution","status":"publish","type":"post","link":"https:\/\/pineele.com\/ko\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution","title":{"rendered":"XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"856\" height=\"837\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869486.webp\" alt=\" PINEELE XGN15-24 Ring Main Unit\" class=\"wp-image-669\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869486.webp 856w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869486-300x293.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869486-768x751.webp 768w\" sizes=\"(max-width: 856px) 100vw, 856px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Introduction to XGN15-12~24 <a href=\"https:\/\/pineele.com\/ko\/xgn66-12-ring-main-unit-high-voltage-switchgear\/\">Ring Main Unit<\/a> by PINEELE<\/strong><\/h2>\n\n\n\n<p>\uadf8\ub9ac\uace0 <strong>PINEELE XGN15-12~24 Ring Main Unit (RMU)<\/strong> is a fixed-type, air-insulated, medium-voltage switchgear system developed for modern distribution networks. Designed to accommodate rated voltages of 12kV or 24kV and a maximum current of 630A, this advanced RMU solution is tailored for high-performance operation in industrial facilities, commercial centers, substations, and urban grid renovation projects.<\/p>\n\n\n\n<p>Using advanced SF6 load switches or vacuum switches, the PINEELE Ring Main Unit ensures reliability, modularity, safety, and expandability. Each unit is constructed with robust armored metal housing, ensuring optimal mechanical strength and insulation while meeting the <strong>IEC60420<\/strong> standard.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp\" alt=\"PINEELE XGN15-12~24 Ring Main Unit\" class=\"wp-image-517\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp 800w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1-300x300.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1-150x150.webp 150w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1-768x768.webp 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Key Features of the PINEELE XGN15-12~24 Ring Main Unit<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Modular Flexibility<\/strong>: Fully modular design allows seamless extension and integration into new or existing systems.<\/li>\n\n\n\n<li><strong>Compact &amp; Efficient<\/strong>: Integrated three-position rotary load switch reduces components and improves switching safety.<\/li>\n\n\n\n<li><strong>High Reliability<\/strong>: Corrosion-resistant operating mechanisms and self-lubricating bearings ensure a long maintenance-free life.<\/li>\n\n\n\n<li><strong>Automation Ready<\/strong>: Supports electric drive units and SCADA compatibility for remote monitoring and control.<\/li>\n\n\n\n<li><strong>User-Friendly Interface<\/strong>: Intuitive single-line diagrams and analog displays for operational status.<\/li>\n\n\n\n<li><strong>Safety First<\/strong>: Five-position mechanical interlocking system prevents human error during operation or maintenance.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"702\" height=\"1024\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-2-702x1024.webp\" alt=\"\" class=\"wp-image-515\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-2-702x1024.webp 702w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-2-206x300.webp 206w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-2-768x1120.webp 768w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-2.webp 790w\" sizes=\"(max-width: 702px) 100vw, 702px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Technical Specifications of PINEELE XGN15-12~24 Ring Main Unit<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Main Technical Data<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Rated Specification<\/th><th>Unit<\/th><th>12kV<\/th><th>24kV<\/th><\/tr><\/thead><tbody><tr><td>\uc815\uaca9 \uc8fc\ud30c\uc218<\/td><td>Hz<\/td><td>50\/60<\/td><td>50\/60<\/td><\/tr><tr><td>Main Busbar Current<\/td><td>A<\/td><td>630<\/td><td>630<\/td><\/tr><tr><td>Branch Busbar Current<\/td><td>A<\/td><td>630<\/td><td>630\/\u2264100\u2461<\/td><\/tr><tr><td>Power Frequency Withstand Voltage (Phase-to-Ground)<\/td><td>kV<\/td><td>42<\/td><td>65<\/td><\/tr><tr><td>Lightning Impulse Withstand Voltage (Phase-to-Ground)<\/td><td>kV<\/td><td>75<\/td><td>85<\/td><\/tr><tr><td>Rated Short-time Withstand Current<\/td><td>kA<\/td><td>20\/3s<\/td><td>25\/2s<\/td><\/tr><tr><td>Rated Peak Withstand Current<\/td><td>kA<\/td><td>50<\/td><td>63<\/td><\/tr><tr><td>Short-Circuit Breaking Current<\/td><td>kA<\/td><td>31.5<\/td><td>31.5<\/td><\/tr><tr><td>Active Load Breaking Current<\/td><td>A<\/td><td>630<\/td><td>630<\/td><\/tr><tr><td>Cable Charging Breaking Current<\/td><td>A<\/td><td>10<\/td><td>25<\/td><\/tr><tr><td>Protection Degree<\/td><td>\u2013<\/td><td>IP3X<\/td><td>IP3X<\/td><\/tr><tr><td>Mechanical Life (Load Switch)<\/td><td>Times<\/td><td>5000<\/td><td>3000<\/td><\/tr><tr><td>Mechanical Life (Grounding Switch)<\/td><td>Times<\/td><td>2000<\/td><td>2000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>Notes: \u2460 Up to the fuse rated current<br>\u2461 Load switch-fuse combination cabinet<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Operating Conditions<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Temperature Range<\/strong>: -15\u00b0C to +40\u00b0C<\/li>\n\n\n\n<li><strong>Altitude<\/strong>: \u22641000m<\/li>\n\n\n\n<li><strong>Relative Humidity<\/strong>: \u226495% daily average<\/li>\n\n\n\n<li><strong>Vapor Pressure<\/strong>: \u22642.2kPa daily \/ \u22641.8kPa monthly<\/li>\n\n\n\n<li><strong>Seismic Tolerance<\/strong>: \u2264Magnitude 8<\/li>\n\n\n\n<li><strong>Environment<\/strong>: Free of corrosive or flammable gases<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Detailed Structure of the XGN15-12~24 Ring Main Unit<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. Busbar Compartment<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Located in the upper section.<\/li>\n\n\n\n<li>Connected main busbars run through the entire cabinet row.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Load Switch Room<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>SF6-filled epoxy resin cast columns ensure superior insulation.<\/li>\n\n\n\n<li>Optional SF6 gas density meters or alarm-enabled meters are available.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. Cable Compartment<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Spacious design facilitates lightning arrester, CTs, grounding switches, etc.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Low-Voltage Control Room<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Houses spring operating mechanisms, keylocks, trip coils, and auxiliary contacts.<\/li>\n\n\n\n<li>Dual control chambers in wider cabinets for accessory expansions.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>5. Interlock Mechanisms<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Five-position interlocks prevent incorrect switching sequences.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"933\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869417-1024x933.webp\" alt=\"\ud30c\uc778\uc560\ud50c \" class=\"wp-image-670\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869417-1024x933.webp 1024w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869417-300x273.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869417-768x699.webp 768w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869417.webp 1041w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Why Choose PINEELE\u2019s XGN15-12~24 Ring Main Unit?<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Trusted Reliability<\/strong>: Built with high-precision components for long-term performance.<\/li>\n\n\n\n<li><strong>Custom Options<\/strong>: Configurable per project needs \u2013 contact our team for tailored RMU units.<\/li>\n\n\n\n<li><strong>Global Standards<\/strong>: Complies with IEC60420 and other international electrical codes.<\/li>\n\n\n\n<li><strong>Compact Excellence<\/strong>: Perfect for space-limited substations or densely populated urban projects.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Ordering Guide<\/strong><\/h2>\n\n\n\n<p>To ensure a smooth customization and installation process, please provide:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Main circuit diagram and busbar configuration.<\/li>\n\n\n\n<li>Required switchgear dimensions.<\/li>\n\n\n\n<li>Desired accessories and quantity.<\/li>\n\n\n\n<li>Any custom modifications or special environmental conditions.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Common Questions About PINEELE Ring Main Unit (RMU)<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Q1: What is the advantage of using SF6 gas in PINEELE Ring Main Units?<\/strong><\/h3>\n\n\n\n<p><strong>A<\/strong>: SF6 gas provides excellent dielectric insulation and arc-quenching properties, significantly enhancing the safety and operational reliability of the Ring Main Unit under high-voltage switching conditions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Q2: Can the XGN15-12~24 Ring Main Unit support remote control and automation?<\/strong><\/h3>\n\n\n\n<p><strong>A<\/strong>: Yes, the PINEELE RMU supports motorized mechanisms and can be integrated into SCADA systems or other automation networks for remote monitoring and real-time control.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Q3: Is the PINEELE RMU suitable for outdoor applications?<\/strong><\/h3>\n\n\n\n<p><strong>A<\/strong>: The standard XGN15-12~24 RMU is designed for indoor use. However, with customized enclosures and IP upgrades, it can be adapted for protected outdoor environments. Please contact us for tailored outdoor solutions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"607\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869426-1024x607.webp\" alt=\"\ud30c\uc778\uc560\ud50c \" class=\"wp-image-671\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869426-1024x607.webp 1024w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869426-300x178.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869426-768x455.webp 768w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/snap_1742869426.webp 1526w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Applications of the PINEELE XGN15-12~24 Ring Main Unit<\/strong><\/h2>\n\n\n\n<p>PINEELE\u2019s Ring Main Unit is widely deployed in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\ub3c4\uc2dc \uc804\ub825\ub9dd<\/strong><\/li>\n\n\n\n<li><strong>Pre-Fabricated Substations<\/strong><\/li>\n\n\n\n<li><strong>Industrial &amp; Mining Facilities<\/strong><\/li>\n\n\n\n<li><strong>Commercial Centers and Shopping Complexes<\/strong><\/li>\n\n\n\n<li><strong>Transportation Infrastructure (Rail, Airports, Ports)<\/strong><\/li>\n\n\n\n<li><strong>Renewable Energy Microgrids and Wind Farms<\/strong><\/li>\n\n\n\n<li><strong>Institutional Facilities such as Universities and Hospitals<\/strong><\/li>\n<\/ul>\n\n\n\n<p>The XGN15-12~24 RMU by PINEELE provides an ideal solution where <strong>medium-voltage reliability<\/strong>, compact layout, and flexible configuration are essential.<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction to XGN15-12~24 Ring Main Unit by PINEELE The PINEELE XGN15-12~24 Ring Main Unit (RMU) is a fixed-type, air-insulated, medium-voltage switchgear system developed for modern distribution networks. Designed to accommodate rated voltages of 12kV or 24kV and a maximum current of 630A, this advanced RMU solution is tailored for high-performance operation in industrial facilities, commercial [&hellip;]<\/p>","protected":false},"author":1,"featured_media":517,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[12],"tags":[],"class_list":["post-668","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ring-main-unit"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution - PINEELE<\/title>\n<meta name=\"description\" content=\"Discover the PINEELE XGN15-12~24 Ring Main Unit \u2013 a compact, air-insulated medium-voltage switchgear for urban, industrial, and automated power systems. Fully modular, SF6 insulated, IEC60420 compliant. Customizable and automation-ready.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pineele.com\/ko\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution - PINEELE\" \/>\n<meta property=\"og:description\" content=\"Discover the PINEELE XGN15-12~24 Ring Main Unit \u2013 a compact, air-insulated medium-voltage switchgear for urban, industrial, and automated power systems. Fully modular, SF6 insulated, IEC60420 compliant. Customizable and automation-ready.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pineele.com\/ko\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution\" \/>\n<meta property=\"og:site_name\" content=\"PINEELE\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-25T02:28:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-25T02:28:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"songshu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\uae00\uc4f4\uc774\" \/>\n\t<meta name=\"twitter:data1\" content=\"songshu\" \/>\n\t<meta name=\"twitter:label2\" content=\"\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\ubd84\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#article\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution\"},\"author\":{\"name\":\"songshu\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\"},\"headline\":\"XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution\",\"datePublished\":\"2025-03-25T02:28:14+00:00\",\"dateModified\":\"2025-03-25T02:28:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution\"},\"wordCount\":696,\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp\",\"articleSection\":[\"Ring Main Unit (RMU)\"],\"inLanguage\":\"ko-KR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution\",\"url\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution\",\"name\":\"XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution - PINEELE\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#primaryimage\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp\",\"datePublished\":\"2025-03-25T02:28:14+00:00\",\"dateModified\":\"2025-03-25T02:28:15+00:00\",\"description\":\"Discover the PINEELE XGN15-12~24 Ring Main Unit \u2013 a compact, air-insulated medium-voltage switchgear for urban, industrial, and automated power systems. Fully modular, SF6 insulated, IEC60420 compliant. Customizable and automation-ready.\",\"breadcrumb\":{\"@id\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#primaryimage\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp\",\"width\":800,\"height\":800},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/pineele.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/pineele.com\/#website\",\"url\":\"https:\/\/pineele.com\/\",\"name\":\"PINEELE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/pineele.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/pineele.com\/#organization\",\"name\":\"PINEELE\",\"url\":\"https:\/\/pineele.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"width\":200,\"height\":50,\"caption\":\"PINEELE\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\",\"name\":\"songshu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"caption\":\"songshu\"},\"sameAs\":[\"https:\/\/pineele.com\/\"],\"url\":\"https:\/\/pineele.com\/ko\/author\/songshu\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution - PINEELE","description":"Discover the PINEELE XGN15-12~24 Ring Main Unit \u2013 a compact, air-insulated medium-voltage switchgear for urban, industrial, and automated power systems. Fully modular, SF6 insulated, IEC60420 compliant. Customizable and automation-ready.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pineele.com\/ko\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution","og_locale":"ko_KR","og_type":"article","og_title":"XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution - PINEELE","og_description":"Discover the PINEELE XGN15-12~24 Ring Main Unit \u2013 a compact, air-insulated medium-voltage switchgear for urban, industrial, and automated power systems. Fully modular, SF6 insulated, IEC60420 compliant. Customizable and automation-ready.","og_url":"https:\/\/pineele.com\/ko\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution","og_site_name":"PINEELE","article_published_time":"2025-03-25T02:28:14+00:00","article_modified_time":"2025-03-25T02:28:15+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp","type":"image\/webp"}],"author":"songshu","twitter_card":"summary_large_image","twitter_misc":{"\uae00\uc4f4\uc774":"songshu","\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04":"5\ubd84"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#article","isPartOf":{"@id":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution"},"author":{"name":"songshu","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3"},"headline":"XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution","datePublished":"2025-03-25T02:28:14+00:00","dateModified":"2025-03-25T02:28:15+00:00","mainEntityOfPage":{"@id":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution"},"wordCount":696,"publisher":{"@id":"https:\/\/pineele.com\/#organization"},"image":{"@id":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp","articleSection":["Ring Main Unit (RMU)"],"inLanguage":"ko-KR"},{"@type":"WebPage","@id":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution","url":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution","name":"XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution - PINEELE","isPartOf":{"@id":"https:\/\/pineele.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#primaryimage"},"image":{"@id":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp","datePublished":"2025-03-25T02:28:14+00:00","dateModified":"2025-03-25T02:28:15+00:00","description":"Discover the PINEELE XGN15-12~24 Ring Main Unit \u2013 a compact, air-insulated medium-voltage switchgear for urban, industrial, and automated power systems. Fully modular, SF6 insulated, IEC60420 compliant. Customizable and automation-ready.","breadcrumb":{"@id":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#primaryimage","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/GTXGN-12-1-1.webp","width":800,"height":800},{"@type":"BreadcrumbList","@id":"https:\/\/pineele.com\/xgn15-1224-ring-main-unit-medium-voltage-air-insulated-switchgear-solution#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pineele.com\/"},{"@type":"ListItem","position":2,"name":"XGN15-12~24 Ring Main Unit \u2013 Medium Voltage Air-Insulated Switchgear Solution"}]},{"@type":"WebSite","@id":"https:\/\/pineele.com\/#website","url":"https:\/\/pineele.com\/","name":"PINEELE","description":"","publisher":{"@id":"https:\/\/pineele.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pineele.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR"},{"@type":"Organization","@id":"https:\/\/pineele.com\/#organization","name":"PINEELE","url":"https:\/\/pineele.com\/","logo":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","width":200,"height":50,"caption":"PINEELE"},"image":{"@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3","name":"songshu","image":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/pineele.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","caption":"songshu"},"sameAs":["https:\/\/pineele.com\/"],"url":"https:\/\/pineele.com\/ko\/author\/songshu"}]}},"_links":{"self":[{"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/posts\/668","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/comments?post=668"}],"version-history":[{"count":3,"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/posts\/668\/revisions"}],"predecessor-version":[{"id":674,"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/posts\/668\/revisions\/674"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/media\/517"}],"wp:attachment":[{"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/media?parent=668"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/categories?post=668"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pineele.com\/ko\/wp-json\/wp\/v2\/tags?post=668"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}