{"id":1273,"date":"2025-04-06T05:04:48","date_gmt":"2025-04-06T05:04:48","guid":{"rendered":"https:\/\/pineele.com\/?p=1273"},"modified":"2025-04-06T05:04:50","modified_gmt":"2025-04-06T05:04:50","slug":"zn28a-12-630-20-vacuum-circuit-breaker","status":"publish","type":"post","link":"https:\/\/pineele.com\/zn28a-12-630-20-vacuum-circuit-breaker","title":{"rendered":"ZN28A-12\/630-20 Vacuum Circuit Breaker"},"content":{"rendered":"\n
TheZN28A-12\/630-20 Vacuum Circuit Breaker is a highly reliable and efficient device designed for medium-voltage indoor applications, with a rated voltage of 12kV and a frequency of 50Hz. It is an essential component for protecting electrical systems in substations, industrial plants, and power distribution networks. TheZN28A-12 series complies with the GB1984-89 standard and is designed to provide optimal protection against overloads, short circuits, and faults, ensuring the safety and longevity of connected equipment.\n\n\n\n TheZN28A-12 vacuum circuit breaker is designed with two main installation forms: an integrated structure and a separated structure. The integrated structure is known as the basic model (ZN28-12), while the separated structure is referred to as the ZN28A-12 type. This flexibility makes it suitable for various fixed switchgear systems, such as CClA(Z) and XGN2A-10(Z), offering versatility in installation and operation.\n\n\n\n The following table provides detailed technical parameters for theZN28A-12\/630-20 Vacuum Circuit Breaker:\n\n\n\n TheZN28A-12\/630-20 Vacuum Circuit Breaker is designed for installation in fixed switchgear and requires an appropriate operating mechanism, such as the CD-10 electromagnetic mechanism or CT-8 spring operating mechanism. The breaker\u2019s installation and the mechanical transmission should ensure that the main shaft\u2019s rotation angle remains within 58\u00b0 \u00b1 1\u00b0, ensuring proper functionality.\n\n\n\nKey Features of the ZN28A-12\/630-20 Vacuum Circuit Breaker\n\n\n\n
\n
\n\n\n\nTechnical Parameters of ZN28A-12\/630-20 Vacuum Circuit Breaker\n\n\n\n
No Item Units Technical Parameters 1 Rated Voltage kV 12 2 Rated Current A 630, 1000, 1250, 1600 3 Rated Short-Circuit Breaking Current kA 20, 25, 31.5 4 Rated Short Circuit Closing Current kA 50, 63, 80 5 Rated Peak Withstand Current kA 50, 63, 80 6 4s Rated Short Circuit Withstand Current kA 20, 25, 31.5 7 Rated Insulation Level Power Frequency Withstand Voltage (Before\/After Rated Breaking) kV 42 (fracture: 48) Impact Withstand Voltage (Before\/After Rated Breaking) kV 75 (fracture: 84) 8 Rated Operation Sequence 75 (fracture: 84) 9 Mechanical Life Times 10,000 10 Rated Short Circuit Current Breaking Times Times 10,000 11 Operating Mechanism Rated Closing Voltage (DC) V 50 12 Operating Mechanism Rated Trip Current (DC) V 110, 220 13 Contact Stroke mm 110, 200 14 Overtravel (Contact Spring Compression Length) mm 11 \u00b1 1 15 Three-Phase Split and Close Bounce Time ms 3.5 \u00b1 0.5 16 Contact Closing Bounce Time ms \u22642 17 Average Opening Speed m\/s \u22642 18 Average Closing Speed m\/s 1.2 \u00b1 0.2 19 Opening Time (At the Highest Operating Voltage) s 0.6 \u00b1 0.2 20 Closing Time s \u22640.05 21 Main Loop Resistance of Each Phase \u03bc\u03a9 \u22640.08 22 Dynamic and Static Contacts Allowable Wear Cumulative Thickness mm 0.1\n\n\n\n Installation and Environmental Conditions\n\n\n\n