{"id":682,"date":"2025-03-25T02:52:48","date_gmt":"2025-03-25T02:52:48","guid":{"rendered":"https:\/\/pineele.com\/?p=682"},"modified":"2025-03-25T02:52:50","modified_gmt":"2025-03-25T02:52:50","slug":"sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","status":"publish","type":"post","link":"https:\/\/pineele.com\/uk\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","title":{"rendered":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Overview<\/h2>\n\n\n\n<p>\u0423 \"The <strong>SZ\u25a1-35KV Oil-Immersed <a href=\"https:\/\/pineele.com\/uk\/electrical-transformer\/oil-immersed-transformer\/\">Transformer<\/a><\/strong> is a highly efficient, on-load voltage regulating transformer designed for power systems operating at 35kV and below. Operating under a frequency of 50Hz, this transformer is a key component in medium and small-sized substations. It provides reliable power distribution for industrial, agricultural, and lighting applications.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"789\" height=\"726\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\" alt=\"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems\" class=\"wp-image-683\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp 789w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621-300x276.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621-768x707.webp 768w\" sizes=\"(max-width: 789px) 100vw, 789px\" \/><\/figure>\n\n\n\n<p>Manufactured with precision and built using advanced domestic and international technology, the SZ\u25a1-35KV transformer incorporates optimized design techniques and modern materials. This results in a more compact structure, enhanced electric and mechanical strength, and superior heat dissipation performance.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Standards Compliance<\/h2>\n\n\n\n<p>This transformer complies with national and international quality standards ensuring safety, durability, and efficient operation.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u0423\u043c\u043e\u0432\u0438 \u0435\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0456\u0457<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u0412\u0438\u0441\u043e\u0442\u0430 \u043d\u0430\u0434 \u0440\u0456\u0432\u043d\u0435\u043c \u043c\u043e\u0440\u044f<\/strong>: \u22641000m<\/li>\n\n\n\n<li><strong>\u0422\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430 \u043d\u0430\u0432\u043a\u043e\u043b\u0438\u0448\u043d\u044c\u043e\u0433\u043e \u0441\u0435\u0440\u0435\u0434\u043e\u0432\u0438\u0449\u0430<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Maximum: +40\u2103<\/li>\n\n\n\n<li>Monthly Average: +30\u2103<\/li>\n\n\n\n<li>Yearly Average: +20\u2103<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Installation Conditions<\/strong>:\n<ul class=\"wp-block-list\">\n<li>Maximum inclination: &lt;3\u00b0<\/li>\n\n\n\n<li>Free from significant dust, corrosive gases, and flammable vapors<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Structural Features<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Iron Core<\/h3>\n\n\n\n<p>The iron core is fabricated using high-grade cold-rolled silicon steel sheets. The core design incorporates:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Fully biased multi-stage joints<\/li>\n\n\n\n<li>Non-punch hole wind cores<\/li>\n\n\n\n<li>Stainless steel stays and epoxy glass tape reinforcement<\/li>\n<\/ul>\n\n\n\n<p>This structure minimizes energy losses and reduces operational noise, ensuring long-term performance.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"996\" height=\"247\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105201854.webp\" alt=\"Structural Features\" class=\"wp-image-684\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105201854.webp 996w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105201854-300x74.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105201854-768x190.webp 768w\" sizes=\"(max-width: 996px) 100vw, 996px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">2. Coil Design<\/h3>\n\n\n\n<p>The winding conductors are manufactured from high-purity oxygen-free copper wires, available as enameled wire or paper-wrapped flat copper wire. The coil structures include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Drum type<\/li>\n\n\n\n<li>Spiral type<\/li>\n\n\n\n<li>Improved spiral<\/li>\n\n\n\n<li>Continuous winding<\/li>\n\n\n\n<li>Staggered layout<\/li>\n<\/ul>\n\n\n\n<p>This design ensures uniform distribution of magnetic flux and prevents hot-spot formation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Oil Tank<\/h3>\n\n\n\n<p>The oil tank is available in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Barrel-type or shielded construction<\/li>\n\n\n\n<li>Corrugated plates or electroplated radiators for cooling<\/li>\n<\/ul>\n\n\n\n<p>Instead of wheels, the base is welded to meet national gauge standards for stable, fixed installation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Safety &amp; Protection Devices<\/h3>\n\n\n\n<p>Based on customer and standard requirements, the transformer can be equipped with:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pressure relief valve<\/li>\n\n\n\n<li>Gas relay<\/li>\n\n\n\n<li>Signal thermometer<\/li>\n\n\n\n<li>Oil conservator<\/li>\n\n\n\n<li>Oil sample valve<\/li>\n\n\n\n<li>Oil filter system<\/li>\n<\/ul>\n\n\n\n<p>These features ensure system integrity during overvoltage or fault conditions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">\u0422\u0435\u0445\u043d\u0456\u0447\u043d\u0456 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">SZ9-35KV Transformer Technical Data<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Rated Capacity (kVA)<\/th><th>H.V (kV)<\/th><th>Tapping Range<\/th><th>L.V (kV)<\/th><th>Connection<\/th><th>No-load Loss (W)<\/th><th>Load Loss (W)<\/th><th>No-load Current (%)<\/th><th>Impedance (%)<\/th><\/tr><tr><td>2000<\/td><td>35<\/td><td>\u00b13\u00d72.5<\/td><td>6.3\/10.5<\/td><td>Yd11<\/td><td>2900<\/td><td>20200<\/td><td>0.9<\/td><td>6.5<\/td><\/tr><tr><td>2500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>3400<\/td><td>22700<\/td><td>0.9<\/td><td><\/td><\/tr><tr><td>3150<\/td><td>35-38.5<\/td><td><\/td><td><\/td><td><\/td><td>4100<\/td><td>26000<\/td><td>0.8<\/td><td>7<\/td><\/tr><tr><td>4000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>4900<\/td><td>30700<\/td><td>0.8<\/td><td><\/td><\/tr><tr><td>5000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>5800<\/td><td>36000<\/td><td>0.75<\/td><td><\/td><\/tr><tr><td>6300<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>7000<\/td><td>38700<\/td><td>0.75<\/td><td>8<\/td><\/tr><tr><td>8000<\/td><td><\/td><td><\/td><td><\/td><td>Ynd11<\/td><td>9900<\/td><td>43000<\/td><td>0.7<\/td><td><\/td><\/tr><tr><td>10000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>11600<\/td><td>50600<\/td><td>0.7<\/td><td><\/td><\/tr><tr><td>12500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>13800<\/td><td>59900<\/td><td>0.7<\/td><td><\/td><\/tr><tr><td>16000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>16200<\/td><td>73000<\/td><td>0.7<\/td><td><\/td><\/tr><tr><td>20000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>19500<\/td><td>84600<\/td><td>0.7<\/td><td><\/td><\/tr><tr><td>25000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>22500<\/td><td>100200<\/td><td>0.7<\/td><td>10<\/td><\/tr><tr><td>31500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>26400<\/td><td>124000<\/td><td>0.6<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">SZ11-35KV Transformer Technical Data<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Rated Capacity (kVA)<\/td><td>H.V (kV)<\/td><td>Tapping Range<\/td><td>L.V (kV)<\/td><td>Connection<\/td><td>No-load Loss (W)<\/td><td>Load Loss (W)<\/td><td>No-load Current (%)<\/td><td>Impedance (%)<\/td><\/tr><tr><td>2000<\/td><td>35<\/td><td>\u00b13\u00d72.5<\/td><td>6.3\/10.5<\/td><td>Yd11<\/td><td>2300<\/td><td>19240<\/td><td>0.8<\/td><td>6.5<\/td><\/tr><tr><td>2500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>2720<\/td><td>20640<\/td><td>0.8<\/td><td><\/td><\/tr><tr><td>3150<\/td><td>35-38.5<\/td><td><\/td><td><\/td><td><\/td><td>3230<\/td><td>24710<\/td><td>0.72<\/td><td>7<\/td><\/tr><tr><td>4000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>3870<\/td><td>29160<\/td><td>0.72<\/td><td><\/td><\/tr><tr><td>5000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>4640<\/td><td>31200<\/td><td>0.68<\/td><td><\/td><\/tr><tr><td>6300<\/td><td><\/td><td><\/td><td>6.3\/6.6\/10.5<\/td><td>Ynd11<\/td><td>5630<\/td><td>36770<\/td><td>0.68<\/td><td>7.5<\/td><\/tr><tr><td>8000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>7870<\/td><td>40610<\/td><td>0.6<\/td><td><\/td><\/tr><tr><td>10000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>9280<\/td><td>48050<\/td><td>0.6<\/td><td><\/td><\/tr><tr><td>12500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>10940<\/td><td>56860<\/td><td>0.56<\/td><td>8<\/td><\/tr><tr><td>16000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>13170<\/td><td>70320<\/td><td>0.54<\/td><td><\/td><\/tr><tr><td>20000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>15570<\/td><td>82780<\/td><td>0.54<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">SZ13-35KV Transformer Technical Data<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Rated Capacity (kVA)<\/td><td>H.V (kV)<\/td><td>Tapping Range<\/td><td>L.V (kV)<\/td><td>Connection<\/td><td>No-load Loss (W)<\/td><td>Load Loss (W)<\/td><td>No-load Current (%)<\/td><td>Impedance (%)<\/td><\/tr><tr><td>2000<\/td><td>35<\/td><td>\u00b13\u00d72.5<\/td><td>6.3\/10.5<\/td><td>Yd11<\/td><td>2300<\/td><td>19200<\/td><td>0.5<\/td><td>6.5<\/td><\/tr><tr><td>2500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>2720<\/td><td>20600<\/td><td>0.5<\/td><td><\/td><\/tr><tr><td>3150<\/td><td>35-38.5<\/td><td><\/td><td><\/td><td><\/td><td>3230<\/td><td>24700<\/td><td>0.5<\/td><td>7<\/td><\/tr><tr><td>4000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>3870<\/td><td>29100<\/td><td>0.5<\/td><td><\/td><\/tr><tr><td>5000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>4640<\/td><td>34200<\/td><td>0.5<\/td><td><\/td><\/tr><tr><td>6300<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>5630<\/td><td>36700<\/td><td>0.5<\/td><td>8<\/td><\/tr><tr><td>8000<\/td><td><\/td><td><\/td><td>6.3\/6.6\/10.5<\/td><td>Ynd11<\/td><td>7870<\/td><td>40600<\/td><td>0.4<\/td><td><\/td><\/tr><tr><td>10000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>9280<\/td><td>48000<\/td><td>0.4<\/td><td><\/td><\/tr><tr><td>12500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>1090<\/td><td>56800<\/td><td>0.35<\/td><td><\/td><\/tr><tr><td>16000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>1310<\/td><td>70300<\/td><td>0.35<\/td><td><\/td><\/tr><tr><td>20000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>1550<\/td><td>82100<\/td><td>0.35<\/td><td><\/td><\/tr><tr><td>25000<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>1830<\/td><td>97800<\/td><td>0.3<\/td><td>10<\/td><\/tr><tr><td>31500<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>2180<\/td><td>716000<\/td><td>0.3<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. What is the purpose of an oil-immersed transformer in modern power systems?<\/h3>\n\n\n\n<p>Oil-immersed transformers provide efficient insulation and superior heat dissipation, making them suitable for medium-voltage networks and industrial applications.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. How does the SZ\u25a1-35KV transformer support voltage regulation?<\/h3>\n\n\n\n<p>The SZ\u25a1-35KV transformer features on-load voltage regulation capability, allowing it to adapt to grid voltage fluctuations in real time without service interruption.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. What makes this transformer energy-efficient?<\/h3>\n\n\n\n<p>With advanced materials, optimized coil and core designs, and reduced no-load and load losses, this transformer significantly improves overall energy efficiency.<\/p>","protected":false},"excerpt":{"rendered":"<p>Overview The SZ\u25a1-35KV Oil-Immersed Transformer is a highly efficient, on-load voltage regulating transformer designed for power systems operating at 35kV and below. Operating under a frequency of 50Hz, this transformer is a key component in medium and small-sized substations. It provides reliable power distribution for industrial, agricultural, and lighting applications. Manufactured with precision and built [&hellip;]<\/p>","protected":false},"author":1,"featured_media":683,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[24],"tags":[],"class_list":["post-682","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oil-immersed-transformer"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE<\/title>\n<meta name=\"description\" content=\"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pineele.com\/uk\/sz\u25a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\" \/>\n<meta property=\"og:locale\" content=\"uk_UA\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE\" \/>\n<meta property=\"og:description\" content=\"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pineele.com\/uk\/sz\u25a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\" \/>\n<meta property=\"og:site_name\" content=\"PINEELE\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-25T02:52:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-25T02:52:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"789\" \/>\n\t<meta property=\"og:image:height\" content=\"726\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"songshu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e\" \/>\n\t<meta name=\"twitter:data1\" content=\"songshu\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u0431\u043b. \u0447\u0430\u0441 \u0447\u0438\u0442\u0430\u043d\u043d\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u0445\u0432\u0438\u043b\u0438\u043d\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#article\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\"},\"author\":{\"name\":\"songshu\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\"},\"headline\":\"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution\",\"datePublished\":\"2025-03-25T02:52:48+00:00\",\"dateModified\":\"2025-03-25T02:52:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\"},\"wordCount\":499,\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\",\"articleSection\":[\"Oil-Immersed Transformer\"],\"inLanguage\":\"uk\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\",\"url\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\",\"name\":\"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\",\"datePublished\":\"2025-03-25T02:52:48+00:00\",\"dateModified\":\"2025-03-25T02:52:50+00:00\",\"description\":\"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.\",\"breadcrumb\":{\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#breadcrumb\"},\"inLanguage\":\"uk\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"uk\",\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp\",\"width\":789,\"height\":726},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/pineele.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/pineele.com\/#website\",\"url\":\"https:\/\/pineele.com\/\",\"name\":\"PINEELE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/pineele.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"uk\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/pineele.com\/#organization\",\"name\":\"PINEELE\",\"url\":\"https:\/\/pineele.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"uk\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"width\":200,\"height\":50,\"caption\":\"PINEELE\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\",\"name\":\"songshu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"uk\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"caption\":\"songshu\"},\"sameAs\":[\"https:\/\/pineele.com\/\"],\"url\":\"https:\/\/pineele.com\/uk\/author\/songshu\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE","description":"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pineele.com\/uk\/sz\u25a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","og_locale":"uk_UA","og_type":"article","og_title":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE","og_description":"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.","og_url":"https:\/\/pineele.com\/uk\/sz\u25a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","og_site_name":"PINEELE","article_published_time":"2025-03-25T02:52:48+00:00","article_modified_time":"2025-03-25T02:52:50+00:00","og_image":[{"width":789,"height":726,"url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp","type":"image\/webp"}],"author":"songshu","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e":"songshu","\u041f\u0440\u0438\u0431\u043b. \u0447\u0430\u0441 \u0447\u0438\u0442\u0430\u043d\u043d\u044f":"4 \u0445\u0432\u0438\u043b\u0438\u043d\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#article","isPartOf":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution"},"author":{"name":"songshu","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3"},"headline":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution","datePublished":"2025-03-25T02:52:48+00:00","dateModified":"2025-03-25T02:52:50+00:00","mainEntityOfPage":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution"},"wordCount":499,"publisher":{"@id":"https:\/\/pineele.com\/#organization"},"image":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp","articleSection":["Oil-Immersed Transformer"],"inLanguage":"uk"},{"@type":"WebPage","@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","url":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution","name":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution - PINEELE","isPartOf":{"@id":"https:\/\/pineele.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage"},"image":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp","datePublished":"2025-03-25T02:52:48+00:00","dateModified":"2025-03-25T02:52:50+00:00","description":"High-performance SZ\u25a1-35KV oil-immersed transformer ideal for 35kV and below power systems, designed for efficient voltage regulation, insulation, and industrial applications.","breadcrumb":{"@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#breadcrumb"},"inLanguage":"uk","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution"]}]},{"@type":"ImageObject","inLanguage":"uk","@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#primaryimage","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/20250325105044621.webp","width":789,"height":726},{"@type":"BreadcrumbList","@id":"https:\/\/pineele.com\/sz%e2%96%a1-35kv-oil-immersed-transformer-for-power-systems-transformer-solution#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pineele.com\/"},{"@type":"ListItem","position":2,"name":"SZ\u25a1-35KV Oil-Immersed Transformer for Power Systems | Transformer Solution"}]},{"@type":"WebSite","@id":"https:\/\/pineele.com\/#website","url":"https:\/\/pineele.com\/","name":"PINEELE","description":"","publisher":{"@id":"https:\/\/pineele.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pineele.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"uk"},{"@type":"Organization","@id":"https:\/\/pineele.com\/#organization","name":"PINEELE","url":"https:\/\/pineele.com\/","logo":{"@type":"ImageObject","inLanguage":"uk","@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","width":200,"height":50,"caption":"PINEELE"},"image":{"@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3","name":"songshu","image":{"@type":"ImageObject","inLanguage":"uk","@id":"https:\/\/pineele.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","caption":"songshu"},"sameAs":["https:\/\/pineele.com\/"],"url":"https:\/\/pineele.com\/uk\/author\/songshu"}]}},"_links":{"self":[{"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/posts\/682","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/comments?post=682"}],"version-history":[{"count":2,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/posts\/682\/revisions"}],"predecessor-version":[{"id":686,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/posts\/682\/revisions\/686"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/media\/683"}],"wp:attachment":[{"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/media?parent=682"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/categories?post=682"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/tags?post=682"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}