{"id":825,"date":"2025-03-29T02:06:32","date_gmt":"2025-03-29T02:06:32","guid":{"rendered":"https:\/\/pineele.com\/?p=825"},"modified":"2025-03-29T05:44:15","modified_gmt":"2025-03-29T05:44:15","slug":"11-33-kv-substation","status":"publish","type":"post","link":"https:\/\/pineele.com\/uk\/11-33-kv-substation","title":{"rendered":"11\/33 kV Substation"},"content":{"rendered":"<h2 class=\"wp-block-heading\">\u0412\u0441\u0442\u0443\u043f<\/h2>\n\n\n\n<p>An <strong>11\/33 kV substation<\/strong> plays a pivotal role in medium voltage power distribution networks. It functions as a critical node for stepping up or stepping down voltages between 33 kilovolts and 11 kilovolts, which are standard voltage levels in many global distribution grids. Whether deployed in urban, rural, or industrial environments, this substation ensures reliable, efficient, and safe power delivery.<\/p>\n\n\n\n<p>Understanding the architecture and functionality of an 11\/33 kV <a href=\"https:\/\/pineele.com\/uk\/unit-substation-transformer\/\" target=\"_blank\" rel=\"noopener\">Substation<\/a> is essential for power engineers, developers, and energy planners. This guide explores the essential substation equipment, configuration, and industry standards associated with 11\/33 kV substations.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/European-Standard-Compact-Substationwebp.webp\" alt=\"11\/33 kV Substation\" class=\"wp-image-409\" srcset=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/European-Standard-Compact-Substationwebp.webp 1000w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/European-Standard-Compact-Substationwebp-300x300.webp 300w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/European-Standard-Compact-Substationwebp-150x150.webp 150w, https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/European-Standard-Compact-Substationwebp-768x768.webp 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">1. What is an 11\/33 kV Substation?<\/h2>\n\n\n\n<p>An <strong>11\/33 kV substation<\/strong> is designed to either step down voltage from 33kV to 11kV or step up from 11kV to 33kV, depending on the network layout. These substations are essential for bridging the gap between high-voltage transmission and low-voltage distribution.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Common Use-Cases:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Stepping down voltage before it enters industrial or commercial zones.<\/li>\n\n\n\n<li>Interfacing between primary and secondary distribution networks.<\/li>\n\n\n\n<li>Serving as grid injection points in renewable energy plants.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">2. Components of 11\/33 kV Substations<\/h2>\n\n\n\n<p>An optimized <strong>substation<\/strong> of this category typically includes:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">a. Power Transformers<\/h3>\n\n\n\n<p>Transformers are the heart of the substation, converting voltage levels with high efficiency. For 11\/33kV, these are often two-winding or three-winding transformers with ONAN\/ONAF cooling.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">b. Switchgear (Indoor\/Outdoor)<\/h3>\n\n\n\n<p>Includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Circuit breakers<\/strong> (Vacuum or SF6)<\/li>\n\n\n\n<li><strong>Disconnectors\/Isolators<\/strong><\/li>\n\n\n\n<li><strong>Load Break Switches (LBS)<\/strong><\/li>\n\n\n\n<li><strong>Earth Switches<\/strong><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">c. Busbars<\/h3>\n\n\n\n<p>These are copper\/aluminum conductors used to distribute power. Depending on reliability needs, substations may use single busbar, double busbar, or ring bus arrangements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">d. Protection Relays<\/h3>\n\n\n\n<p>Modern substations are integrated with IEDs (Intelligent Electronic Devices) compliant with <strong>IEC 61850<\/strong>. Common relays include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Overcurrent<\/li>\n\n\n\n<li>Differential<\/li>\n\n\n\n<li>Distance protection<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">e. Lightning Arresters and Surge Protectors<\/h3>\n\n\n\n<p>Prevent transient overvoltages from damaging equipment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">f. Auxiliary Systems<\/h3>\n\n\n\n<p>Battery banks, battery chargers, and lighting systems.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">3. Technical Specifications Table<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th><th>Typical Range<\/th><\/tr><tr><td>Primary Voltage<\/td><td>33 kV<\/td><\/tr><tr><td>Secondary Voltage<\/td><td>11 kV<\/td><\/tr><tr><td>Frequency<\/td><td>50 Hz<\/td><\/tr><tr><td>Transformer Rating<\/td><td>500 kVA to 10 MVA<\/td><\/tr><tr><td>Short Circuit Level<\/td><td>25-31.5 kA for 3 sec<\/td><\/tr><tr><td>Breaker Type<\/td><td>VCB \/ SF6<\/td><\/tr><tr><td>Relay Communication<\/td><td>IEC 61850, Modbus, DNP3<\/td><\/tr><tr><td>Earthing Resistance<\/td><td>&lt; 1 ohm (typical)<\/td><\/tr><tr><td>Insulation Coordination<\/td><td>BIL 170 kVp<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">4. Substation Design Considerations<\/h2>\n\n\n\n<p>Designing a high-performance substation involves several layers:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">a. Load Forecasting<\/h3>\n\n\n\n<p>Calculate peak loads to size equipment appropriately.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">b. Protection Coordination<\/h3>\n\n\n\n<p>Ensure relays and breakers operate selectively to isolate only the faulted section.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">c. Layout Planning<\/h3>\n\n\n\n<p>Determine whether to use <strong>outdoor<\/strong> or <strong>indoor switchgear<\/strong>, GIS (Gas Insulated Switchgear), or AIS (Air Insulated).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">d. Environmental Factors<\/h3>\n\n\n\n<p>Include seismic, wind, and temperature stress resilience.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">e. Safety and Maintenance Access<\/h3>\n\n\n\n<p>Adequate clearance and safety interlocks are critical.<\/p>\n\n\n\n<p>![Image Placeholder: Substation Protection Scheme Diagram]<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">5. Applications of 11\/33 kV Substations<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Industrial parks<\/li>\n\n\n\n<li>Large commercial zones<\/li>\n\n\n\n<li>Solar and wind farms<\/li>\n\n\n\n<li>Government installations<\/li>\n\n\n\n<li>Urban and peri-urban electrical grids<\/li>\n<\/ul>\n\n\n\n<p>These substations are often used to feed 11kV ring main units (RMUs) in dense areas.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">6. Compliance and International Standards<\/h2>\n\n\n\n<p>Every <strong>substation<\/strong> must conform to:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>IEC 62271-100 \/ 200 (High-voltage switchgear)<\/li>\n\n\n\n<li>IS 1180 (Distribution Transformers)<\/li>\n\n\n\n<li>IEEE 1584 (Arc Flash Analysis)<\/li>\n\n\n\n<li>ISO 45001 (Occupational safety)<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">7. Substation Installation &amp; Commissioning Steps<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">a. Site Preparation<\/h3>\n\n\n\n<p>Surveying, excavation, and concrete foundations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">b. Equipment Delivery &amp; Erection<\/h3>\n\n\n\n<p>Placement of transformers, panels, breakers, and bus ducts.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">c. Cable Termination &amp; Earthing<\/h3>\n\n\n\n<p>Ensuring proper grounding and cable insulation testing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">d. Pre-Commissioning Tests<\/h3>\n\n\n\n<p>IR value tests, primary\/secondary injection, relay settings.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">e. Final Testing &amp; Energization<\/h3>\n\n\n\n<p>Systematic start-up with monitoring for voltage sags\/swells.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">8. Advantages of 11\/33kV Substations<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Improved voltage regulation<\/li>\n\n\n\n<li>Efficient load management<\/li>\n\n\n\n<li>Flexible and modular deployment<\/li>\n\n\n\n<li>High level of operational safety<\/li>\n\n\n\n<li>Automation-ready configuration<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">9. Frequently Asked Questions (FAQs)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Q1: What\u2019s the difference between 11kV, 33kV, and 11\/33kV substations?<\/h3>\n\n\n\n<p><strong>A1:<\/strong> 11kV and 33kV substations operate at fixed voltage levels. 11\/33kV substations bridge these two, offering flexibility in network transitions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Q2: How is maintenance carried out for such substations?<\/h3>\n\n\n\n<p><strong>A2:<\/strong> Regular thermographic analysis, relay testing, transformer oil tests, and alert systems guide preventive maintenance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Q3: What are common faults in 11\/33 kV substations?<\/h3>\n\n\n\n<p><strong>A3:<\/strong> Transformer overloads, breaker trip faults, insulation failures, and communication errors are typical.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>An <strong>11\/33 kV substation<\/strong> is a robust, scalable, and essential component of power infrastructure. It ensures seamless power flow between different voltage levels, enabling grid stability, optimized energy distribution, and reliability across sectors.<\/p>\n\n\n\n<p>With increasing focus on automation and renewable integration, 11\/33 kV substations are becoming more intelligent and efficient than ever before. Investing in well-designed substations helps mitigate outages, supports load growth, and builds a smarter energy future.<\/p>","protected":false},"excerpt":{"rendered":"<p>Introduction An 11\/33 kV substation plays a pivotal role in medium voltage power distribution networks. It functions as a critical node for stepping up or stepping down voltages between 33 kilovolts and 11 kilovolts, which are standard voltage levels in many global distribution grids. Whether deployed in urban, rural, or industrial environments, this substation ensures [&hellip;]<\/p>","protected":false},"author":1,"featured_media":736,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-825","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-compact-substation"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>11\/33 kV Substation - PINEELE<\/title>\n<meta name=\"description\" content=\"Explore a complete overview of 11\/33 kV substations, covering technical specifications, design insights, essential components, real-world applications, and SEO-optimized substation terminology.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pineele.com\/uk\/11-33-kv-substation\/\" \/>\n<meta property=\"og:locale\" content=\"uk_UA\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"11\/33 kV Substation - PINEELE\" \/>\n<meta property=\"og:description\" content=\"Explore a complete overview of 11\/33 kV substations, covering technical specifications, design insights, essential components, real-world applications, and SEO-optimized substation terminology.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pineele.com\/uk\/11-33-kv-substation\/\" \/>\n<meta property=\"og:site_name\" content=\"PINEELE\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-29T02:06:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-29T05:44:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/image.png\" \/>\n\t<meta property=\"og:image:width\" content=\"472\" \/>\n\t<meta property=\"og:image:height\" content=\"368\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"songshu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e\" \/>\n\t<meta name=\"twitter:data1\" content=\"songshu\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u0431\u043b. \u0447\u0430\u0441 \u0447\u0438\u0442\u0430\u043d\u043d\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u0445\u0432\u0438\u043b\u0438\u043d\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation#article\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation\"},\"author\":{\"name\":\"songshu\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\"},\"headline\":\"11\/33 kV Substation\",\"datePublished\":\"2025-03-29T02:06:32+00:00\",\"dateModified\":\"2025-03-29T05:44:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation\"},\"wordCount\":709,\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/image.png\",\"articleSection\":[\"Compact Substation\"],\"inLanguage\":\"uk\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation\",\"url\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation\",\"name\":\"11\/33 kV Substation - PINEELE\",\"isPartOf\":{\"@id\":\"https:\/\/pineele.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation#primaryimage\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation#primaryimage\"},\"thumbnailUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/image.png\",\"datePublished\":\"2025-03-29T02:06:32+00:00\",\"dateModified\":\"2025-03-29T05:44:15+00:00\",\"description\":\"Explore a complete overview of 11\/33 kV substations, covering technical specifications, design insights, essential components, real-world applications, and SEO-optimized substation terminology.\",\"breadcrumb\":{\"@id\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation#breadcrumb\"},\"inLanguage\":\"uk\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/pineele.com\/fr\/11-33-kv-substation\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"uk\",\"@id\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation#primaryimage\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/image.png\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/image.png\",\"width\":472,\"height\":368},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/pineele.com\/fr\/11-33-kv-substation#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/pineele.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"11\/33 kV Substation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/pineele.com\/#website\",\"url\":\"https:\/\/pineele.com\/\",\"name\":\"PINEELE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/pineele.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/pineele.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"uk\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/pineele.com\/#organization\",\"name\":\"PINEELE\",\"url\":\"https:\/\/pineele.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"uk\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"contentUrl\":\"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp\",\"width\":200,\"height\":50,\"caption\":\"PINEELE\"},\"image\":{\"@id\":\"https:\/\/pineele.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3\",\"name\":\"songshu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"uk\",\"@id\":\"https:\/\/pineele.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g\",\"caption\":\"songshu\"},\"sameAs\":[\"https:\/\/pineele.com\/\"],\"url\":\"https:\/\/pineele.com\/uk\/author\/songshu\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"11\/33 kV Substation - PINEELE","description":"Explore a complete overview of 11\/33 kV substations, covering technical specifications, design insights, essential components, real-world applications, and SEO-optimized substation terminology.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pineele.com\/uk\/11-33-kv-substation\/","og_locale":"uk_UA","og_type":"article","og_title":"11\/33 kV Substation - PINEELE","og_description":"Explore a complete overview of 11\/33 kV substations, covering technical specifications, design insights, essential components, real-world applications, and SEO-optimized substation terminology.","og_url":"https:\/\/pineele.com\/uk\/11-33-kv-substation\/","og_site_name":"PINEELE","article_published_time":"2025-03-29T02:06:32+00:00","article_modified_time":"2025-03-29T05:44:15+00:00","og_image":[{"width":472,"height":368,"url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/image.png","type":"image\/png"}],"author":"songshu","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e":"songshu","\u041f\u0440\u0438\u0431\u043b. \u0447\u0430\u0441 \u0447\u0438\u0442\u0430\u043d\u043d\u044f":"4 \u0445\u0432\u0438\u043b\u0438\u043d\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/pineele.com\/fr\/11-33-kv-substation#article","isPartOf":{"@id":"https:\/\/pineele.com\/fr\/11-33-kv-substation"},"author":{"name":"songshu","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3"},"headline":"11\/33 kV Substation","datePublished":"2025-03-29T02:06:32+00:00","dateModified":"2025-03-29T05:44:15+00:00","mainEntityOfPage":{"@id":"https:\/\/pineele.com\/fr\/11-33-kv-substation"},"wordCount":709,"publisher":{"@id":"https:\/\/pineele.com\/#organization"},"image":{"@id":"https:\/\/pineele.com\/fr\/11-33-kv-substation#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/image.png","articleSection":["Compact Substation"],"inLanguage":"uk"},{"@type":"WebPage","@id":"https:\/\/pineele.com\/fr\/11-33-kv-substation","url":"https:\/\/pineele.com\/fr\/11-33-kv-substation","name":"11\/33 kV Substation - PINEELE","isPartOf":{"@id":"https:\/\/pineele.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pineele.com\/fr\/11-33-kv-substation#primaryimage"},"image":{"@id":"https:\/\/pineele.com\/fr\/11-33-kv-substation#primaryimage"},"thumbnailUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/image.png","datePublished":"2025-03-29T02:06:32+00:00","dateModified":"2025-03-29T05:44:15+00:00","description":"Explore a complete overview of 11\/33 kV substations, covering technical specifications, design insights, essential components, real-world applications, and SEO-optimized substation terminology.","breadcrumb":{"@id":"https:\/\/pineele.com\/fr\/11-33-kv-substation#breadcrumb"},"inLanguage":"uk","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pineele.com\/fr\/11-33-kv-substation"]}]},{"@type":"ImageObject","inLanguage":"uk","@id":"https:\/\/pineele.com\/fr\/11-33-kv-substation#primaryimage","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/image.png","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/image.png","width":472,"height":368},{"@type":"BreadcrumbList","@id":"https:\/\/pineele.com\/fr\/11-33-kv-substation#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pineele.com\/"},{"@type":"ListItem","position":2,"name":"11\/33 kV Substation"}]},{"@type":"WebSite","@id":"https:\/\/pineele.com\/#website","url":"https:\/\/pineele.com\/","name":"PINEELE","description":"","publisher":{"@id":"https:\/\/pineele.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pineele.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"uk"},{"@type":"Organization","@id":"https:\/\/pineele.com\/#organization","name":"PINEELE","url":"https:\/\/pineele.com\/","logo":{"@type":"ImageObject","inLanguage":"uk","@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/","url":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","contentUrl":"https:\/\/pineele.com\/wp-content\/uploads\/2025\/03\/cropped-PINEELE-logo-168x34-1.webp","width":200,"height":50,"caption":"PINEELE"},"image":{"@id":"https:\/\/pineele.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/pineele.com\/#\/schema\/person\/f9d5678223d9ef2c898499805fd338a3","name":"songshu","image":{"@type":"ImageObject","inLanguage":"uk","@id":"https:\/\/pineele.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/00431e6324439a6d7d267eeec22a104fb1e7a0f1a31f178add79c76e6110f4d3?s=96&d=identicon&r=g","caption":"songshu"},"sameAs":["https:\/\/pineele.com\/"],"url":"https:\/\/pineele.com\/uk\/author\/songshu"}]}},"_links":{"self":[{"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/posts\/825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/comments?post=825"}],"version-history":[{"count":4,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/posts\/825\/revisions"}],"predecessor-version":[{"id":829,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/posts\/825\/revisions\/829"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/media\/736"}],"wp:attachment":[{"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/media?parent=825"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/categories?post=825"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pineele.com\/uk\/wp-json\/wp\/v2\/tags?post=825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}