Beranda Switchgear Tegangan Tinggi Ring Main Unit (RMU) XGN15-12~24 Ring Main Unit – Medium Voltage Air-Insulated Switchgear Solution
XGN15-12~24 Ring Main Unit – Medium Voltage Air-Insulated Switchgear Solution
XGN15-12~24 Ring Main Unit – Medium Voltage Air-Insulated Switchgear Solution

XGN15-12~24 Ring Main Unit – Medium Voltage Air-Insulated Switchgear Solution

Model: XGN15-12~24
Layanan OEM dan ODM: Tersedia
Kandang: Standar PINEELE
Merek: PINEELE, Merek di Bawah ZHENGXI
Formulir: Tipe Semua Paket
Lingkup Aplikasi: Cocok untuk distribusi daya industri, stabilisasi tegangan, dan perlindungan transformator. Banyak digunakan pada bangunan komersial, pabrik, dan gardu utilitas.
Ditinjau oleh: Zheng Ji,Insinyur Listrik Senior di PINEELE
18+ tahun pengalaman dalam desain & pengujian switchgear HV.
Diterbitkan Pada: Maret 25, 2025
Terakhir diperbarui: Maret 25, 2025
Telepon Email WhatsApp
Daftar Isi
  • Introduction to XGN15-12~24 Ring Main Unit by PINEELE
  • Key Features of the PINEELE XGN15-12~24 Ring Main Unit
  • Technical Specifications of PINEELE XGN15-12~24 Ring Main Unit
  • Main Technical Data
  • Kondisi Operasi
  • Detailed Structure of the XGN15-12~24 Ring Main Unit
  • 1. Busbar Compartment
  • 2. Load Switch Room
  • 3. Cable Compartment
  • 4. Low-Voltage Control Room
  • 5. Interlock Mechanisms
  • Why Choose PINEELE’s XGN15-12~24 Ring Main Unit?
  • Ordering Guide
  • Common Questions About PINEELE Ring Main Unit (RMU)
  • Q1: What is the advantage of using SF6 gas in PINEELE Ring Main Units?
  • Q2: Can the XGN15-12~24 Ring Main Unit support remote control and automation?
  • Q3: Is the PINEELE RMU suitable for outdoor applications?
  • Applications of the PINEELE XGN15-12~24 Ring Main Unit
 PINEELE XGN15-24 Ring Main Unit

Introduction to XGN15-12~24Ring Main Unitby PINEELE

ThePINEELE XGN15-12~24 Ring Main Unit (RMU)is a fixed-type, air-insulated, medium-voltage switchgear system developed for modern distribution networks. Designed to accommodate rated voltages of 12kV or 24kV and a maximum current of 630A, this advanced RMU solution is tailored for high-performance operation in industrial facilities, commercial centers, substations, and urban grid renovation projects.

Using advanced SF6 load switches or vacuum switches, the PINEELE Ring Main Unit ensures reliability, modularity, safety, and expandability. Each unit is constructed with robust armored metal housing, ensuring optimal mechanical strength and insulation while meeting theIEC60420standard.


PINEELE XGN15-12~24 Ring Main Unit

Key Features of the PINEELE XGN15-12~24 Ring Main Unit

  • Modular Flexibility: Fully modular design allows seamless extension and integration into new or existing systems.
  • Compact & Efficient: Integrated three-position rotary load switch reduces components and improves switching safety.
  • High Reliability: Corrosion-resistant operating mechanisms and self-lubricating bearings ensure a long maintenance-free life.
  • Automation Ready: Supports electric drive units and SCADA compatibility for remote monitoring and control.
  • User-Friendly Interface: Intuitive single-line diagrams and analog displays for operational status.
  • Safety First: Five-position mechanical interlocking system prevents human error during operation or maintenance.


Technical Specifications of PINEELE XGN15-12~24 Ring Main Unit

Main Technical Data

Rated SpecificationUnit12kV24kV
Frekuensi yang DinilaiHz50/6050/60
Main Busbar CurrentA630630
Branch Busbar CurrentA630630/≤100②
Power Frequency Withstand Voltage (Phase-to-Ground)kV4265
Lightning Impulse Withstand Voltage (Phase-to-Ground)kV7585
Rated Short-time Withstand CurrentkA20/3s25/2s
Rated Peak Withstand CurrentkA5063
Short-Circuit Breaking CurrentkA31.531.5
Active Load Breaking CurrentA630630
Cable Charging Breaking CurrentA1025
Protection Degree-IP3XIP3X
Mechanical Life (Load Switch)Times50003000
Mechanical Life (Grounding Switch)Times20002000

Notes: ① Up to the fuse rated current
② Load switch-fuse combination cabinet


Kondisi Operasi

  • Kisaran Suhu: -15°C to +40°C
  • Ketinggian: ≤1000m
  • Relative Humidity: ≤95% daily average
  • Vapor Pressure: ≤2.2kPa daily / ≤1.8kPa monthly
  • Seismic Tolerance: ≤Magnitude 8
  • Environment: Free of corrosive or flammable gases

Detailed Structure of the XGN15-12~24 Ring Main Unit

1. Busbar Compartment

  • Located in the upper section.
  • Connected main busbars run through the entire cabinet row.

2. Load Switch Room

  • SF6-filled epoxy resin cast columns ensure superior insulation.
  • Optional SF6 gas density meters or alarm-enabled meters are available.

3. Cable Compartment

  • Spacious design facilitates lightning arrester, CTs, grounding switches, etc.

4. Low-Voltage Control Room

  • Houses spring operating mechanisms, keylocks, trip coils, and auxiliary contacts.
  • Dual control chambers in wider cabinets for accessory expansions.

5. Interlock Mechanisms

  • Five-position interlocks prevent incorrect switching sequences.

PINEELE

Why Choose PINEELE’s XGN15-12~24 Ring Main Unit?

  • Trusted Reliability: Built with high-precision components for long-term performance.
  • Custom Options: Configurable per project needs – contact our team for tailored RMU units.
  • Global Standards: Complies with IEC60420 and other international electrical codes.
  • Compact Excellence: Perfect for space-limited substations or densely populated urban projects.

Ordering Guide

To ensure a smooth customization and installation process, please provide:

  1. Main circuit diagram and busbar configuration.
  2. Required switchgear dimensions.
  3. Desired accessories and quantity.
  4. Any custom modifications or special environmental conditions.

Common Questions About PINEELE Ring Main Unit (RMU)

Q1: What is the advantage of using SF6 gas in PINEELE Ring Main Units?

A: SF6 gas provides excellent dielectric insulation and arc-quenching properties, significantly enhancing the safety and operational reliability of the Ring Main Unit under high-voltage switching conditions.


Q2: Can the XGN15-12~24 Ring Main Unit support remote control and automation?

A: Yes, the PINEELE RMU supports motorized mechanisms and can be integrated into SCADA systems or other automation networks for remote monitoring and real-time control.


Q3: Is the PINEELE RMU suitable for outdoor applications?

A: The standard XGN15-12~24 RMU is designed for indoor use. However, with customized enclosures and IP upgrades, it can be adapted for protected outdoor environments. Please contact us for tailored outdoor solutions.


PINEELE

Applications of the PINEELE XGN15-12~24 Ring Main Unit

PINEELE’s Ring Main Unit is widely deployed in:

  • Urban Power Grids
  • Pre-Fabricated Substations
  • Industrial & Mining Facilities
  • Commercial Centers and Shopping Complexes
  • Transportation Infrastructure (Rail, Airports, Ports)
  • Renewable Energy Microgrids and Wind Farms
  • Institutional Facilities such as Universities and Hospitals

The XGN15-12~24 RMU by PINEELE provides an ideal solution wheremedium-voltage reliability, compact layout, and flexible configuration are essential.

Produk terkait

Air-12T630-25 Gas-Insulated Switchgear
Air-12T630-25 Gas-Insulated Switchgear
Lihat Sekarang

Air-12T630-25 Gas-Insulated Switchgear

GTXGN-12 Metal-Clad Switchgear
GTXGN-12 Metal-Clad Switchgear
Lihat Sekarang

GTXGN-12 Metal-Clad Switchgear

TBB High Voltage Compensation Cabinet – Intelligent Reactive Power Management Solution for 6kV/10kV Systems
TBB High Voltage Compensation Cabinet – Intelligent Reactive Power Management Solution for 6kV/10kV Systems
Lihat Sekarang

TBB High Voltage Compensation Cabinet – Intelligent Reactive Power Management Solution for 6kV/10kV Systems

KYN28-24 Metal-Clad Switchgear – Withdrawable Medium Voltage Power Distribution Solution
KYN28-24 Metal-Clad Switchgear – Withdrawable Medium Voltage Power Distribution Solution
Lihat Sekarang

KYN28-24 Metal-Clad Switchgear – Withdrawable Medium Voltage Power Distribution Solution

XGN66-12 Ring Main Unit – High Voltage Switchgear for 3.6–12kV Distribution Systems
XGN66-12 Ring Main Unit – High Voltage Switchgear for 3.6–12kV Distribution Systems
Lihat Sekarang

XGN66-12 Ring Main Unit – High Voltage Switchgear for 3.6–12kV Distribution Systems

Unit Utama Cincin XGN15-12
Unit Utama Cincin XGN15-12
Lihat Sekarang

Unit Utama Cincin XGN15-12

XGN2-12 Ring Main Unit (RMU) – Metal-Enclosed High Voltage Switchgear for 12kV Power Distribution
XGN2-12 Ring Main Unit (RMU) – Metal-Enclosed High Voltage Switchgear for 12kV Power Distribution
Lihat Sekarang

XGN2-12 Ring Main Unit (RMU) – Metal-Enclosed High Voltage Switchgear for 12kV Power Distribution

SRM6-12 Gas-Insulated Switchgear – Fully Sealed Inflatable Ring Main Unit for 10kV/6kV Power Distribution
SRM6-12 Gas-Insulated Switchgear – Fully Sealed Inflatable Ring Main Unit for 10kV/6kV Power Distribution
Lihat Sekarang

SRM6-12 Gas-Insulated Switchgear – Fully Sealed Inflatable Ring Main Unit for 10kV/6kV Power Distribution

HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear
HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear
Lihat Sekarang

HXGN17-12 Ring Main Unit (RMU) | Medium Voltage Switchgear

Tentang Kami
Kebijakan Privasi
Kebijakan Pengembalian Dana
Kebijakan Garansi

Katalog Gratis
Layanan & Bantuan Pelanggan
Peta Situs
Hubungi Kami

Kotak Percabangan Kabel
Gardu Induk Ringkas
Trafo Listrik
Komponen Tegangan Tinggi
Switchgear Tegangan Tinggi
Switchgear Tegangan Rendah
Berita

PINEELE
  • Facebook
  • LinkedIn
  • Pinterest
  • Twitter

©1999 -PINEELE Semua hak cipta dilindungi undang-undang.
Dilarang mereproduksi materi yang terkandung di sini dalam format atau media apa pun tanpa izin tertulis dari PINEELE Electric Group Co, Ltd.

Selamat datang di PINEELE!
  • Beranda
  • Produk
    • Gardu Induk Ringkas
      • Gardu Induk Ringkas Gaya Amerika
      • Gardu Induk Ringkas Standar Cina
      • Gardu Induk Ringkas Standar Eropa
    • Trafo Listrik
      • Trafo Tipe Kering
      • Trafo Terendam Minyak
    • Kotak Percabangan Kabel
    • Switchgear Tegangan Tinggi
      • Switchgear Berinsulasi Gas
      • Kabinet Kompensasi Tegangan Tinggi
      • Switchgear Berbalut Logam
      • Ring Main Unit (RMU)
    • Switchgear Tegangan Rendah
      • Switchgear Tipe Tetap
    • Komponen Tegangan Tinggi
      • Kontaktor Vakum AC
      • Trafo Arus
      • Sakelar Pemutus
      • Sakelar Pembumian
      • Isolator Listrik
      • Sekering Tegangan Tinggi
      • Sakelar Pemutus Beban
      • Penahan Lonjakan
      • Pemutus Sirkuit Vakum
  • Tentang Kami
  • Hubungi Kami
  • Berita

Jika Anda memiliki pertanyaan, membutuhkan dukungan teknis, atau memerlukan bantuan dengan pesanan, jangan ragu untuk menghubungi kami.

📞 Telepon & WhatsApp

+86 180-5886-8393

📧 Kontak Email

Pertanyaan Umum & Penjualan: [email protected]

Dukungan Teknis: [email protected]

Kami menggunakan cookie untuk meningkatkan pengalaman Anda di situs web kami. Dengan menjelajahi situs web ini, Anda menyetujui penggunaan cookie kami.
Pelajari Lebih Lanjut Tentang Kebijakan Privasi Kami Menerima
Menu
Katalog Gratis
Tentang Kami
[]