Cela isilinganiso
Thola amasampula wamahhala
Cela ikhathalogi yamahhala
- Isingeniso Pinele Gtxgn-12 Metal-Clad Switchchear
- Izici ezibalulekile zePinele Gtxggn-12 Metal-Clad Switchchear
- Isakhiwo esivalelwe ngensimbi esigcwele
- Ukucushwa okuguquguqukayo nomunyu
- Amandla aphezulu we-dielectric namandla
- Ukuphepha okuthuthukisiwe ngama-interlocks
- Ukucaciswa kobuchwepheshe
- Ukubuka konke
- Izinzuzo zePinele GTXGN-12 Metal-Clad Switchchear
- Umgomo Wokusebenza Nokusebenza
- Izinzuzo zohlelo lokusebenza
- Imibuzo ebuzwa njalo (i-FAQ)
- 1. Uyini umehluko phakathi kwensimbi-clad kanye nensimbi evaliwe yensimbi?
- 2. Can Pinele GTXGN-12 zenziwe ngezifiso ezenzakalelayo namagridi ahlakaniphile?
- 3. Iziphi izimboni ezivame ukusebenzisa i-metal-clad switchgear?
- Izimo Zokusebenza
Isingeniso Pinele GTXGN-12I-Metal-Clad switchgear
Le khasiPineele GTXGN-12 Metal-Clad Switchchearuhlelo oluphakathi lwe-voltage switchchear lwenzelwe i-Indoor ezintathu-isigabaAC 50 / 60hzAmanethiwekhi Amandla ane-voltage ekalweI-12kv. I-Metal-Clad switchgearInikeza isixazululo esithambile, esijwayelekile, nesiphephile sokusatshalaliswa kwamandla eziteshini zamandla, izindawo zezimboni, izakhiwo zentengiso, nezinhlelo zokusebenza zamandla avuselelekayo.
Ukuvumelana namazinga aphesheya anjengeIEC 62271-200na-GB3906, theI-GTXGG-12 Metal-Clad SwitchchearIsebenzisaAbaphula umjikelezo we-vacuum,izingxenye eziqinile igesi, futhiizinhlelo zamabhasi ezivalekile zensimbi. ukusindisa isikhala, ukuphepha kwabasebenzi, futhiukuqhubeka kwensiza okuqhubekayozibalulekile.

Izici ezibalulekile zePinele Gtxggn-12 Metal-Clad Switchchear
Isakhiwo esivalelwe ngensimbi esigcwele
- Iyunithi ngalinye elisebenzayo (umfukophisho, ibhasi, ikhebula, ukulawulwa) kuvalwe uphawu futhi kuhlukaniswe ngokuzimela.
- Ukwakhiwa kwezinga lobufakazi obuphakeme futhiIP4X / IP2XUkuvikelwa kokuphepha kwabasebenzi.
Ukucushwa okuguquguqukayo nomunyu
- Yakhelwe bobabiliibhasi elilodwana-ibhasi ephindwe kabiliIzinhlelo ezinamasu okuzithandela we-bypass.
- Amamojula asuselwa kwizandla ahoxisekayo ukuze alungiswe kalula futhi ahlolwe.
Amandla aphezulu we-dielectric namandla
- Ubuchwepheshe be-Vacuum Break ethuthukisiwe buqinisekisa impilo yesevisi ende futhi banciphise ukuguguleka kwe-arc.
- Kuhlolwe ukumelana nesizungu esifushane, amandla e-dielectric, kanye nokungavikeleki ngokwengxenye.
Ukuphepha okuthuthukisiwe ngama-interlocks
- Ukuhlangana okuhlanganisiwe kwemishini kanye nogesi ukuvikela ukufinyelela ngesikhathi sokusebenza bukhoma.
- Kuvimbela ukubheja kwesekethe ukubheja, ukufuya ukushintsha kabi, kanye nokuvula umnyango ngaphansi komthwalo.

Ukucaciswa kobuchwepheshe
Into yendaba | Umuvo | Gtxgn-12 |
---|---|---|
Amandla kagesi | ingoma eleva | Okuqophele |
Imvamisa ekalwe | Hz | I-50/60 |
Kukalwe manje | A | I-630/1250/1600/2000/2500 |
Kukalwe ukuqhekeka okufushane kwesekethe | izinhlamvu | 20 / 25/111.5 |
Kukalwe isizungu esifushane ukwenza manje (Peak) | izinhlamvu | 50/63/80 |
Kukalwe isikhathi esifushane sesikhathi samanje | izinhlamvu | 20 / 25/11.5 (4S) |
I-peak ephakeme imelana namanje | izinhlamvu | 50/63/80 |
UnyaziUkumelana namandla kagesi | ingoma eleva | 75/95 (Isigaba / Umhlaba) |
UbuqhwagaImvamisa imelana namandla kagesi | ingoma eleva | 42 (1 imiz) |
Iziqu Zokuvikelwa | - | I-IP4X (ebiyelwe), IP2X (Izakhiwo) |
Impilo Yomshini (Breaker Circuit) | Izikhathi | I-10,000 - 20,000 |
Izinga lokushisa elikhona | ℃ | -15 kuya ku- +40 |
Ukuphakama phezu kolwandle | uhlobo | ≤1000 (ngokwezifiso kuyatholakala) |
Ukuswakama | U- | ≤95 r RHE |
Uhlobo lokufaka | - | -Ngaphakathi endlini |
Usayizi weKhabhinethi (WXDXH) | m | I-800 × 1500 × 233 2300 (iyahlukahluka) |
Ukubuka konke
Le khasiPineele GTXGN-12 Metal-Clad Switchchearyakhiwa:
- A. Igumbi lokuphuka kwesifunda
Izindlu iyunithi ye-vacuum circuit breaker youthi (vs1 noma efanayo). - B. Igumbi leBusbar
Itholakala phezulu, ngensimbi efinyeleleke ngokuphelele futhi ifakwe ukuphepha okuphezulu. - C. Igumbi lekhebula
Itholakala ezansi esikhaleni esanele sezindawo zokugcina, ama-CTS, kanye nababhalisile abahlinzwa. - D. Igumbi Lensimbi
Ifakwe ngaphambili ngokudluliselwa kwamamitha, amamitha kanye nama-terminals okuxhumana.
Izinzuzo zePinele GTXGN-12 Metal-Clad Switchchear
- Izindawo eziphephile nezivaliwe
I-Metal Partitions iqeda ukusakazwa kwe-arc futhi ithuthukise ukuphepha opharetha. - Ukuhoxiswa Kwendlela
I-Trolley ekhiphekayo ye-trolley yokubuyiselwa okusheshayo nokulungisa. - Ukuqapha Smart Ready
Iyahambisana ne-scada / DCS futhi ifakwe oxhumana nabo abasizayo nezinzwa. - Izidingo zokulungiswa okuphansi
Isebenzisa iziphazamiso ze-vacuum mahhala zesondlo kanye nezindawo ezivalwe ngothuli. - Idizayini eyenziwe ngokwezifiso
Usekela amazinga endawo, ukwakheka kwebhasi ngokwezifiso, nezinhlobo ezahlukahlukene zokudlulisa.
Umgomo Wokusebenza Nokusebenza
Le khasiI-GTXGG-12 Metal-Clad Switchchearithola amandla aphakathi nendawo anamandla avela kuma-feeders angenayo futhi awasabalali ngemigqa ephumayo ngeAbaphula umjikelezo we-vacuum.
Le khasiI-Main Breaker HandcartIngahanjiswa phakathi kwensizakalo, isivivinyo, nezikhundla ezinqamuliwe ngenkathi i-switchgear ihlala inamandla, iqinisekisa isikhathi esiphezulu sengozi encane.
Izinzuzo zohlelo lokusebenza
UkuhambisaPineele GTXGN-12 Metal-Clad Switchchearimiphumela:
- Ukuncishiswa kwamandla okuncishisiwe kusuka ekukhipheni okuyingxenye kanye ne-Polict Polictor empofu
- Imijikelezo ethuthukisiwe yokulungisa nge-modular and elula-access design
- Ukucushwa kwenethiwekhi okuguquguqukayo kufaka phakathi ama-grid afakiwe kanye nama-radial
- Ukusekelwa kwesizukulwane esisatshalaliswa, ukuhlanganiswa okuvuselelekayo, kanye nama-micrograds
Imibuzo ebuzwa njalo (i-FAQ)
1. Uyini umehluko phakathi kwensimbi-clad kanye nensimbi evaliwe yensimbi?
I-Metal-Clad switchgearInengxenye ngayinye ebukhoma ebiyelwe egumbini layo lensimbi eliphansi, linikeza ukuvikela okuphezulu kwe-arc nokuphepha okusebenzayo. kuvalwe insimbiIzinhlobo kungenzeka ziye zabelana ngezindawo ezifakiwe ngaphandle kokuhlukaniswa okugcwele.
2. Can Pinele GTXGN-12 zenziwe ngezifiso ezenzakalelayo namagridi ahlakaniphile?
Yebo. Isikhumba,amayunithi esikhumbuzo esikude (RTUS), futhiUkudluliselwa Kokuvikelwa KwengqondoUkuthunyelwa kwe-Smart Grid nokuqapha kwamandla wesikhathi sangempela.
3. Iziphi izimboni ezivame ukusebenzisa i-metal-clad switchgear?
Le khasiPineele GTXGN-12 Metal-Clad Switchchearisetshenziswa kabanzi ku:
- Isizukulwane samandla kanye nezingane
- Amafutha negesi Industries
- Izitshalo zokwelashwa kwamanzi
- Izinkambu zamandla avuselelekayo
- Iziteshi zeMetro / Railway kanye Nemigudu
- Izitshalo zezimboni kanye nezakhiwo zezentengiselwano
Izimo Zokusebenza
Le khasiI-GTXGG-12 Metal-Clad Switchchearilungele:
- Izindawo ezenzakalelayo zezimboni
- Amanethiwekhi asabalalisa aphakathi nendawo
- Izakhiwo Zentengiso Nengqalasizinda
- Izinhlelo zomoya kanye ne-solar Energy
- Ama-Hubs ezokuthutha kanye nezitho ezingaphansi komhlaba
- I-Smart City kanye ne-IOT-Ready Power Systems