- Introduction to Ring Main Unit (RMU)
- Core Working Principle of Switchgear RMU
- Key Operating Elements:
- Application Fields
- Market Trends and Background
- Technical Parameters (Typical RMU Specification)
- Comparison with Conventional Switchgear
- Selection and Purchasing Guide
- Authority References
- 자주 묻는 질문(FAQ)
- Conclusion
Introduction to Ring Main Unit (RMU)
A 링 메인 유닛(RMU) is a compact, sealed switchgear assembly used in medium voltage (MV) power distribution networks. It plays a crucial role in ensuring uninterrupted power delivery and offers multiple configuration options for managing feeders and transformers. RMUs are commonly found in secondary distribution substations, especially in urban environments where space is limited.

Core Working Principle of Switchgear RMU
The working principle of an RMU revolves around the looped network configuration. In this setup, the incoming and outgoing feeders form a “ring,” allowing electricity to flow from two directions. This topology ensures redundancy—if one side of the loop fails or requires maintenance, the other continues supplying power, minimizing outages.
At the heart of the RMU are switches 그리고 circuit breakers housed within gas-insulated or air-insulated enclosures. The most common type uses SF₆ gas insulation for its high dielectric strength and compact size.
Key Operating Elements:
- Load Break Switches: Interrupt current under load.
- 회로 차단기: Protect against short circuits and overloads.
- Earthing Switches: Safely ground disconnected lines.
- Isolators: Visibly isolate parts of the circuit for maintenance.
Application Fields
Ring Main Units are widely used in:
- Urban electrical distribution networks
- Renewable energy systems (wind, solar)
- Industrial facilities
- Hospitals, malls, and commercial complexes
- Underground cable systems
Their modular structure, enhanced safety, and low maintenance make them ideal for modern power distribution.
Market Trends and Background
에 따르면 IEEE and market intelligence by IEEMA, the global demand for compact MV switchgear like RMUs is rising due to:
- Rapid urbanization and need for space-saving electrical solutions
- Growth in renewable energy integration
- Emphasis on grid reliability and resilience
The transition to smart grids 그리고 automated substations is also driving innovation in RMU technology, with features like remote control, SCADA integration, and self-diagnostic systems becoming common.
Technical Parameters (Typical RMU Specification)
Parameter | Value |
---|---|
Rated Voltage | 12kV – 24kV |
Rated Current | 630A – 1250A |
Short Circuit Breaking Capacity | Up to 25kA for 3 seconds |
Insulation Medium | SF₆ gas / Air / Solid |
Degree of Protection | IP4X / IP65 (gas tank) |
Operating Temperature | -25°C to +55°C |
Mechanical Endurance | ≥ 10,000 operations |
Standards Compliance | IEC 62271-200, IEC 60265 |
Comparison with Conventional Switchgear
Feature | RMU | Conventional MV Switchgear |
---|---|---|
Size | Compact | Bulky |
Insulation Type | SF₆ / Solid | Air / Oil |
Maintenance | Minimal | Regular |
Installation Type | Indoor/Outdoor | Typically Indoor |
Switching Elements | Load Break + Circuit Breaker | Mostly Circuit Breaker |
RMUs are especially advantageous in locations with space constraints and require less frequent servicing compared to air-insulated switchgear.
Selection and Purchasing Guide
When selecting an RMU, consider the following:
- Voltage and current ratings
- Type of insulation (SF₆, solid, or air)
- Number of feeders required
- Protection mechanism (fuse or circuit breaker)
- Installation environment (indoor or outdoor)
- Remote control requirements (for smart grid compatibility)
Top manufacturers include ABB, 슈나이더 일렉트릭, Siemens, and Eaton, offering a wide range of configurable RMU solutions.
Authority References
- IEEE Xplore: MV Switchgear and Distribution
- Wikipedia: Ring Main Unit
- Schneider Electric RMU Brochure
- ABB Medium Voltage Distribution Catalog
자주 묻는 질문(FAQ)
A1: The RMU ensures uninterrupted power by allowing looped connections. Even if one feeder fails, the other keeps supplying electricity.
A2: SF₆ is a potent greenhouse gas, but RMUs are sealed and designed to prevent leakage. Modern alternatives include solid-insulated RMUs to reduce environmental impact.
A3: Yes, many RMUs support SCADA integration, remote switching, and real-time monitoring, making them suitable for automated and intelligent grid systems.
Conclusion
The 링 메인 유닛(RMU) is a key component in modern medium voltage power networks, offering flexibility, safety, and space efficiency. Understanding its working principle, technical specifications, and application scenarios helps engineers and buyers make informed decisions. As smart grids and renewables grow, RMUs will continue to play a central role in reliable power distribution.
이 페이지의 인쇄용 버전을 PDF로 받아보세요.